跳转至内容
Merck
CN
  • Evaluation of the matrix effect of different sample matrices for 33 pharmaceuticals by post-column infusion.

Evaluation of the matrix effect of different sample matrices for 33 pharmaceuticals by post-column infusion.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2015-07-27)
Julia Rossmann, Robert Gurke, Lars David Renner, Reinhard Oertel, Wilhelm Kirch
摘要

Matrix effects that occur during quantitative measurement by liquid chromatography mass spectrometry specifically when using electrospray ionization are a widely recognized phenomenon. Sample matrix compounds affect the ionization process of the target analytes, lead to a low signal response, and flawed analytical results. How these matrix compounds directly influence the ionization process has not yet been completely understood. In the present study, we determined the matrix effect for 33 pharmaceutical substances in sample extracts of urine, plasma and wastewater. Most of the investigated substances were subject to a signal suppression effect. Only for a small subset of the compounds we detected a signal enhancement effect. We investigated the matrix effect profiles in detail to disentangle the influence of different matrices and to correlate the impact of specific components and groups of the analyzed extract in suppressing or enhancing effects in the profile. Most signal suppression effects were detected in the first half of the chromatographic run-time for the matrix extracts of urine and wastewater. The observed effects are caused by high mass flow of salts and other diverse matrix components that were contained in high concentrations in those biological matrices. We also found signal suppression in the matrix effect profile of plasma samples over a wide time range during the chromatographic separation that were associated with a high content of triglycerides of diverse carbohydrate chain lengths. Here, we provide a broader picture of how 33 substances were influenced during analysis. Our results imply that a high number of the investigated substances had comparable effects of matrix compounds, despite differences in their chemical structure.

材料
货号
品牌
产品描述

Sigma-Aldrich
氟康唑, ≥98% (HPLC), powder
Sigma-Aldrich
甲酸, ≥95%, FCC, FG
Sigma-Aldrich
氯氮平标准液
Supelco
Pregabalin solution, 1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
Sigma-Aldrich
氟哌啶醇, powder
Supelco
加巴喷丁标准液 CRM 溶液, 1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
Sigma-Aldrich
拉莫三嗪, ≥98%, powder
Supelco
卡马西平标准液 溶液, 1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
Sigma-Aldrich
加巴喷丁, solid
Supelco
氯氮平标准液 溶液, 1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
Supelco
Levetiracetam solution, 1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
Supelco
奥氮平标准液 CRM 溶液, 1.0 mg/mL in acetonitrile, ampule of 1 mL, certified reference material, Cerilliant®
Supelco
Lamotrigine solution, 1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
Supelco
Topiramate solution, 1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
Supelco
Risperidone solution, 1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
Supelco
米氮平 溶液, 1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
Supelco
Haloperidol solution, 1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
Supelco
普里米酮, 1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
Sigma-Aldrich
奥卡西平, ≥98% (HPLC), solid
Supelco
O-Desmethylvenlafaxine solution, 100 μg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
Supelco
阿替洛尔标准溶液 溶液, 1.0 mg/mL in acetonitrile, ampule of 1 mL, certified reference material, Cerilliant®
Supelco
10,11-Dihydro-10-Hydroxycarbamazepine solution, 1.0 mg/mL in acetonitrile, ampule of 1 mL, certified reference material, Cerilliant®
Supelco
氟康唑标准液 溶液, 2.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
Sigma-Aldrich
卡马西平, meets USP testing specifications