If you decide to place an order during this period, we reserve the right to adjust the price based on the evolving situation. We understand that market changes may cause inconvenience. We will negotiate with you if there’s a significant price fluctuation due to tariff policy changes before the order’s actual delivery, and in such cases we may adjust or cancel the order as necessary.

Merck
CN
HomeCell Counting & Health AnalysisOptimized PCR-based Detection of Mycoplasma

Optimized PCR-based Detection of Mycoplasma

Why is mycoplasma contamination a serious problem for cell cultures?

The maintenance of contamination-free cell lines is essential to cell-based research. Among the biggest contaminant concerns are mycoplasma contamination. Although mycoplasma do not usually kill contaminated cells, they are difficult to detect and can cause a variety of effects on cultured cells, including altered metabolism, slowed proliferation and chromosomal aberrations. In short, mycoplasma contamination compromises the value of those cell lines in providing accurate data for life science research.

Common sources of mycoplasma contamination of cell cultures, and tips for prevention

The sources of mycoplasma contamination in the laboratory are very challenging to completely control. As certain mycoplasma species are found on human skin, they can be introduced through poor aseptic technique. Additionally, they can come from contaminated supplements such as fetal bovine serum, and most importantly from other contaminated cell cultures. Once mycoplasma contaminates a culture, it can quickly spread to contaminate other areas of the lab. Strict adherence to good laboratory practices such as good aseptic technique are key, and routine testing for mycoplasma is highly recommended for successful control of mycoplasma contamination.

Video tutorial for mycoplasma PCR-based testing kit (MP0035)

PCR-based detection of mycoplasma has become a very popular method for routine cell line maintenance, and is typically the method employed by cell repositories that offer mycoplasma detection services, as well as for protecting their own stocks. PCR-based detection methods are highly sensitive and can provide rapid results, which allows researchers to respond quickly to isolate and eliminate contamination once it is detected in comparison to the time required using microbiological techniques. The LookOut Mycoplasma PCR Detection Kit is highly sensitive, with a detection limit of only 2 genomes per μL.

Which PCR reagents for mycoplasma are the most sensitive and specific?

Specific results from PCR screening for mycoplasma can be enhanced with careful reagent selection. JumpStart Taq DNA Polymerase minimizes non-specific sequence amplification and maximizes yield, enhancing both specificity and sensitivity. The LookOut Mycoplasma PCR kit also uses a proprietary primer design, significantly reducing the potential for false positive results. The 8-tube format and strips pre-coated with dNTPs helps increase the throughput to meet the needs of customers with larger collections of cell lines.

Due to the extreme sensitivity of the kit, strict aseptic technique should be followed to prevent inadvertent contamination of samples and reagents. The step-by-step video protocol clearly demonstrates necessary precautions and best practices required for reliable mycoplasma detection at a fraction of the cost of sending samples out for testing. To ensure success with the method, the video protocol includes typical results and discusses their interpretation.

产品编号产品名称说明价格
11498045910Actin RNA Probe, DIG-labeledsolution, pkg of 2 μg
11093657910DIG DNA标记和检测试剂盒
11175033910DIG DNA标记试剂盒sufficient for 40 labeling reactions, kit of 1 (7 components), suitable for hybridization
11277065910DIG DNA标记混合物
03353591910DIG 凝胶迁移试剂盒,第2storage temp.:-20°C (-15°C to -25°C)
11585606910DIG-High Primesufficient for 40 labeling reactions, pkg of 160 μL, solution
11745832910DIG-High Prime DNA标记及检测启动装Isufficient for 12 labeling reactions, sufficient for 24 blots, suitable for hybridization, suitable for Northern blotting, suitable for Southern blotting
11585614910DIG-High Prime DNA标记及检测启动装IIsufficient for 12 labeling reactions (10 ng to 3 μg per assay), sufficient for 24 blots (blots of 100 cm2)
11585738910DIG-labeled Control DNAsolution, pkg of 50 μL (5 μg/ml DIG-labeled plasmid DNA)
11363514910DIG发光检测试剂盒sufficient for 50 blots (10 cm x 10 cm each), kit of 1 (5 components), suitable for hybridization
11745816910DIG-切口平移混合物sufficient for 40 labeling reactions, pkg of 160 μL, suitable for hybridization
12039672910DIG Northern 启动试剂盒suitable for Northern blotting, sufficient for 10 labeling reactions
11175041910DIG核酸检测试剂盒sufficient for 40 blots (10 cm x 10 cm each), kit of 1 (5 components), suitable for hybridization, suitable for Northern blotting
03353575910DIG寡核苷酸3′-末端标记试剂盒,第2代sufficient for 25 labeling reactions (100 pmol of oligonucleotides per assay; 1 ug of a 30-mer oligonucleotide), storage condition avoid repeated freeze/thaw cycles
03353583910DIG 寡核苷酸拖尾试剂盒,第2 sufficient for 25 reactions (100 pmol oligonucleotide per assay; 1 ug of a 30-mer oligonucleotide)
11333089001抗-地高辛from sheep
11333062910抗 地高辛from mouse IgG1κ (clone 1.71.256)
11093274910抗地高辛-AP,Fab片段from sheep
11214667001抗 地高辛,Fab 片段from sheep