跳转至内容
Merck
CN
  • Magnetic resonance imaging of single co-labeled mesenchymal stromal cells after intracardial injection in mice.

Magnetic resonance imaging of single co-labeled mesenchymal stromal cells after intracardial injection in mice.

RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin (2014-04-01)
J Salamon, D Wicklein, M Didié, C Lange, U Schumacher, G Adam, K Peldschus
摘要

The aim of this study was to establish co-labeling of mesenchymal stromal cells (MSC) for the detection of single MSC in-vivo by MRI and histological validation. Mouse MSC were co-labeled with fluorescent iron oxide micro-particles and carboxyfluorescein succinimidyl ester (CFSE). The cellular iron content was determined by atomic absorption spectrometry. Cell proliferation and expression of characteristic surface markers were determined by flow cytometry. The chondrogenic differentiation capacity was assessed. Different amounts of cells (n1 = 5000, n2 = 15 000, n3 = 50 000) were injected into the left heart ventricle of 12 mice. The animals underwent sequential MRI on a clinical 3.0 T scanner (Intera, Philips Medical Systems, Best, The Netherlands). For histological validation cryosections were examined by fluorescent microscopy. Magnetic and fluorescent labeling of MSC was established (mean cellular iron content 23.6 ± 3 pg). Flow cytometry showed similar cell proliferation and receptor expression of labeled and unlabeled MSC. Chondrogenic differentiation of labeled MSC was verified. After cell injection MRI revealed multiple signal voids in the brain and fewer signal voids in the kidneys. In the brain, an average of 4.6 ± 1.2 (n1), 9.0 ± 3.6 (n2) and 25.0 ± 1.0 (n3) signal voids were detected per MRI slice. An average of 8.7 ± 3.1 (n1), 22.0 ± 6.1 (n2) and 89.8 ± 6.5 (n3) labeled cells per corresponding stack of adjacent cryosections could be detected in the brain. Statistical correlation of the numbers of MRI signal voids in the brain and single MSC found by histology revealed a correlation coefficient of r = 0.91. The study demonstrates efficient magnetic and fluorescent co-labeling of MSC and their detection on a single cell level in mice by in-vivo MRI and histology. The described techniques may broaden the methods for in-vivo tracking of MSC. • Detection of single magnetically labeled MSC in-vivo using a clinical 3.0 T MRI is possible.• Fluorescent and magnetic co-labeling does not affect cell vitality.• The number of cells detected by MRI and histology has a high correlation.

材料
货号
品牌
产品描述

Sigma-Aldrich
葡聚糖 来源于明串珠菌 属, Mr 450,000-650,000
Sigma-Aldrich
葡聚糖 来源于明串珠菌 属, Mr ~70,000
Sigma-Aldrich
葡聚糖 来源于明串珠菌 属, Mr ~40,000
Sigma-Aldrich
葡聚糖 溶液 来源于肠系膜明串珠菌, 20 % (w/w) (Autoclaved)
Sigma-Aldrich
葡聚糖 来源于肠系膜明串珠菌, average mol wt 1,500,000-2,800,000
Sigma-Aldrich
葡聚糖 来源于肠系膜明串珠菌, average mol wt 9,000-11,000
Sigma-Aldrich
葡聚糖 来源于肠系膜明串珠菌, average mol wt 60,000-76,000
Sigma-Aldrich
葡聚糖 来源于肠系膜明串珠菌, average mol wt 35,000-45,000
Sigma-Aldrich
葡聚糖 来源于明串珠菌 属, Mr ~6,000
Sigma-Aldrich
葡聚糖 来源于肠系膜明串珠菌, average mol wt 150,000
Supelco
右旋糖酐, analytical standard, for GPC, 25,000
Supelco
右旋糖酐, analytical standard, for GPC, 5,000
Sigma-Aldrich
葡聚糖 来源于明串珠菌 属, Mr ~100,000
Supelco
右旋糖酐, analytical standard, for GPC, 1,000
Supelco
右旋糖酐, analytical standard, for GPC, Set Mp 1,000-400,000
Sigma-Aldrich
葡聚糖 来源于肠系膜明串珠菌, Mr ~200,000
Supelco
右旋糖酐, analytical standard, for GPC, 270,000
Supelco
右旋糖酐, analytical standard, for GPC, 80,000
Supelco
右旋糖酐, analytical standard, for GPC, 150,000
Sigma-Aldrich
葡聚糖 来源于肠系膜明串珠菌, average mol wt 48,000-90,000
Sigma-Aldrich
右旋糖酐, enzymatic synth.
Sigma-Aldrich
葡聚糖 来源于肠系膜明串珠菌, Mr ~60,000
Supelco
葡聚糖 来源于肠系膜明串珠菌, analytical standard, for GPC, Mw 670,000
Supelco
右旋糖酐, analytical standard, for GPC, 50,000
Sigma-Aldrich
葡聚糖 来源于明串珠菌 属, Mr 15,000-25,000
Supelco
葡聚糖 来源于肠系膜明串珠菌, analytical standard, for GPC, Mw 5,000
Supelco
右旋糖酐, analytical standard, for GPC, 670,000
Supelco
葡聚糖 来源于肠系膜明串珠菌, analytical standard, for GPC, Mw 25,000
Sigma-Aldrich
葡聚糖 来源于肠系膜明串珠菌, average mol wt 15,000-30,000
Supelco
葡聚糖 来源于肠系膜明串珠菌, analytical standard, for GPC, Mw 50,000