跳转至内容
Merck
CN

LC/MS/MS Analysis of DL-d-Hydroxyglutaric Acid Enantiomers on Astec® CHIROBIOTIC® R

LC/MS/MS Analysis of DL-d-Hydroxyglutaric Acid Enantiomers on Astec® CHIROBIOTIC® R application for HPLC

材料

分析色谱柱

产品编号
说明
价格

Astec® CHIROBIOTIC® R手性HPLC柱

5 μm particle size, L × I.D. 25 cm × 4.6 mm

标准

产品编号
说明
价格

2-羟基-D-谷氨酸 二钠盐

≥95% (GC)

L-α-羟基戊二酸 二钠盐

≥98.0% (GC)

DL-α-羟基戊二酸 二钠盐

≥95.0% (GC)

相关产品

产品编号
说明
价格

DL-异柠檬酸 三钠盐 水合物

≥93%

α-酮戊二酸钠 钠盐

BioUltra

异柠檬酸盐测定试剂盒

sufficient for 100 colorimetric tests

Isocitrate Dehydrogenase 1 (NADP+) human

recombinant, expressed in Sf9 cells, ≥90% (SDS-PAGE)

IDH 活性检测试剂盒

sufficient for 100 colorimetric tests

CONDITIONS

column

CHIROBIOTIC R, 25 cm x 4.6 mm I.D., 5 μm particles (13024AST)

mobile phase

(A) ethanol:methanol (3:1, v:v); (B) 0.1% v/v TEA in water, adjusted to pH 4.5 with acetic acid; 75:25 (A:B)

flow rate

0.4 mL/min

column temp.

20 °C

detector

MS, ESI(-), 100-1000 m/z

injection

5 μL

sample

each enantiomer, 100 μg/mL in water

说明

分析说明

Chiral 2-hydroxyglutarates (2-OHG) are important molecular signatures of both healthy and diseased biological cells, their specific biochemical pathways and inborn errors of metabolism. The chiral differentiation and quantification of D-2-OHG (R(-)-2-OHG) and L-2-OHG (S(+)-2-OHG) is key for characterizing neurometabolic disorders like the 2-hydroxyglutaric acidurias that cause neurological impairment early in life. The ability to distinguish and quantify the enantiomers of 2-OHG is therefore important to be able to track its disposition throughout the metabolic pathway of normal vs. mutated cells. We show here a rapid and sensitive method to separate and measure D-2-OHG and L-2-OHG using LC-MS/MS detection. An Astec® CHIROBIOTIC R (ristocetin chiral selector) column was run under polar ionic mobile phase conditions. Using tandem MS eliminated two fundamental analytical challenges with these compounds: the lack of a UV-absorbing chromophore in the 2-OHG molecule, and the abundance of competing low molecular weight acids in urine. The upper panel in the chromatogram shows the separation of D-2-OHG and L-2-OHG obtained during method development. The lower panel shows the pure L-2-hydroxyglutaric acid.
Besides providing the necessary enantioselectivity, Astec® CHIROBIOTIC columns have the advantage of operating in aqueous and polar organic mobile phases that are amenable to polar drugs and metabolites. Their ionic interactions promote analyte ionization which enhances sensitivity in ESI detection. In addition to the CHIROBIOTIC columns, Sigma-Aldrich also provides the high purity mobile phase agents, racemic and pure chiral 2-OHG enantiomers and other compounds in the isocitrate dehydrogenase (IDH) pathway.

法律信息

Astec is a registered trademark of Merck KGaA, Darmstadt, Germany
CHIROBIOTIC is a registered trademark of Sigma-Aldrich Co. LLC