物料
polysulfone filter
质量水平
包装
pkg of 1 unit
制造商/商品名称
BioPak®
技术
ELISA: suitable
PCR: suitable
cell culture | mammalian: suitable
相容性
for use with Milli-Q® EQ 7000
for use with Milli-Q® EQ 7008
for use with Milli-Q® EQ 7016
for use with Milli-Q® IX 7003
for use with Milli-Q® IX 7005
for use with Milli-Q® IX 7010
for use with Milli-Q® IX 7015
for use with Milli-Q® IQ 7000
for use with Milli-Q® IQ 7003
for use with Milli-Q® IQ 7005
for use with Milli-Q® IQ 7010
for use with Milli-Q® IQ 7015
运输
ambient
正在寻找类似产品? 访问 产品对比指南
一般描述
应用
Biopak® Polisher推荐用于各种需要控制细菌、热源、核酸酶和/或蛋白酶水平的实验室应用。
这包括小干扰RNA(siRNA)研究、RNA原位杂交、微阵列开发、或蛋白质合成机制的研究。
特点和优势
- 最大限度降低核酸酶、蛋白酶、热原或细菌污染的风险。
- 消除了对DEPC等有毒试剂的需求,从而提高安全性,节省时间并降低成本。
- 底部尖端经重新设计,可安全地安装保护罩。
- 易于维护:精纯柱易于安装替换;无需灭菌。
- 用于将 RFID 与 POD 连接的 e-Sure 标签可在 POD 触摸屏界面上实现完全可追溯性(数据管理)和消耗状态自动监测。
其他说明
生物截留:细菌和热原
作用机制:超滤
应用:细胞培养基、分子生物学
预期用途:减少生物负荷
使用说明:这一产品通过超滤中空纤维提供水过滤。请参阅产品包装插页“更换”部分。
储存声明:干燥储存
处置声明:根据国家、省市和当地适用法规处置。
- 热原(内毒素)< 0.001 EU/mL
- RNA 酶 < 1 pg/mL
- DNA酶 < 5 pg/mL
- 蛋白酶 < 0.15 μg/mL
- 细菌 < 0.01 CFU/mL
法律信息
通常也和此产品一起购买
How frequently do the various consumables need to be changed?
The frequency that consumables must be changed depends on the system's usage (treated water volume) and on the consumables themselves (time of usage). In order to ensure the quality of water and your results, the consumables should be replaced when the system alerts you.
What is the consumables delivery time?
Refer to the consumable's Product page for a first estimation of its expected delivery time and contact customer service for more information.
How are consumables changed?
To help you to change your system's consumables, several video tutorials are available on our YouTube channel: Milli-Q®System Care Tutorials. For high-flow systems, please keep in mind that all consumable changes must be approved by a 3-digit code that only the person in charge of the system knows.
What is the shelf life for Filter?
The shelf life is 2 years for all consumables kept in the recommended storage conditions (temperatures from 5 to 30°C; humidity between 10 and 80%). Contact your local representative for more information.
Can I arrange to have my consumables automatically ordered and delivered once a year?
It's possible to place only one consumable order per year with a specific contract called "Consumable Supply Agreement (CSA)" For further information, contact your local representative or sales contact.
Where can I find data sheets, Certificates of Origin, Certificates of Analysis, and Certificates of Quality?
Documents and certificates are available in the "Documentation" section on this page. Do not hesitate to contact us if you require further information.
What steps are you taking towards improved sustainability?
Sustainability is at the heart of our innovations. From reducing water and energy consumption, to minimizing plastic and chemical waste, our dedicated water system engineers are constantly working on new ways to reduce the ecological footprint of our products to better support the sustainability goals we’re all striving towards. For more information, we invite you to review the following brochure and infographic which highlight our efforts and achievements: link. Do not hesitate to contact your local representative for further information.
How can I know which consumables can be used with my system?
To know which consumables can be used on your system, you can see in the user manual of you system or see it on the following webpage of consumables. All the consumables for each system are indicated.
If I have a final filter that I use only occasionally (e.g., Biopak®) and have another filter (e.g. Millipak®) that I most of the time, can I keep the 'occasional-use' filter for use again at a later time?
It is not possible to re-use a filter that has been used and then removed because air intake during replacement creates an airlock and blocks water passing through the filter. If you regularly need two different filters, we recommend using two POD dispensers.
Can consumables be opened and refilled?
Unfortunately, this is not possible because of safety issues and the need to guarantee the quality of consumables and their interior purification components. Our consumables are manufactured in an ISO 9001-certified facility France in agreement with high quality standards.
商品
An ultrafiltration cartridge can be placed at the outlet of a water purification system to deliver nuclease-free ultrapure water.
Learn how water impurities can affect PCR and related methodologies. High purity water purified using ultrafiltration is suitable for PCR and related techniques.
Nuclease-free water (or PCR water) is needed in molecular biology to avoid sample degradation during PCR, sequencing, etc. Ultrafiltration provides a quicker, safer, and more sustainable alternative to DEPC treatment when preparing RNase-free and DNase-free water.
Milli-Q® 系统产出的超纯水不含BPA,适合用于胚胎学研究,最大限度地减少内分泌干扰物的干扰。
相关内容
Electrophysiology assays: Importance of ultrapure water and Biopak® cartridge filtration to avoid contamination.
Learn how water impurities can affect DNA and RNA electrophoresis and blotting. High purity water purified using ultrafiltration is suitable for nucleic acid electrophoresis, Northern and Southern blotting.
Milli-Q®超纯水始终为您的科研工作注入信心。探索我们的扩展型系统以了解实验室纯水解决方案如何全面满足您的需求并突破实验室瓶颈。
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门