技术
HPLC: suitable
试验参数
column: Ascentis Express C18, 10 cm x 3.0 mm I.D., 2.7 μm particles (53814-U)
mobile phase: [A] 0.1% formic acid in water; [B] 0.1% formic acid in water:acetonitrile (10:90)
gradient: 20% B held for 3 min; 20 to 100% B in 0.1 min; 100% B held for 2 min
flow rate: 0.5 mL/min
pressure: 2150 psi (148 bar)
column temp.: 35 °C
detector: UV, 315 nm
injection: 2 μL
sample: 17 μg/mL each in acetonitrile
适用性
application for HPLC
应用
forensics and toxicology
分析说明
Synthetic cannabinoids (e.g. "Spice") are a type of designer drug that provides a cannabis-type high. New synthetic cannabinoids are continually being introduced as suppliers tweak the molecular structures. The ability to rapidly and reliably identify the continually changing population of these compounds is a significant analytical challenge facing forensic chemists. A rapid separation of six of these compounds on an Ascentis Express C18 column is shown here. The highest grade LC-MS solvents were used to supply low background interference and low particulate contaminants for robust, trouble-free operation. Cerilliant CRMs provided reliable identification and quantification.
法律信息
Ascentis is a registered trademark of Merck KGaA, Darmstadt, Germany
分析物
说明
JWH-073 4-Butanoic acid metabolite solution, 100 μg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
JWH-018 5-Pentanoic acid metabolite solution, 100 μg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
JWH-073 solution, 100 μg/mL in acetonitrile, ampule of 1 mL, certified reference material, Cerilliant®
JWH-018 solution, 100 μg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
分析色谱柱
标准
产品编号
说明
价格
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门