跳转至内容

Dear Customer:

The current international situation is complex and volatile, and uncertain tariff policies may potentially impact our product prices. Given these uncertainties, we value your understanding regarding order-related matters.

If you decide to place an order during this period, we reserve the right to adjust the price based on the evolving situation. We understand that market changes may cause inconvenience. We will negotiate with you if there’s a significant price fluctuation due to tariff policy changes before the order’s actual delivery, and in such cases we may adjust or cancel the order as necessary.

Merck
CN
所有图片(1)

主要文件

53829-U

Supelco

Ascentis® Express 90 Å C18 (2.7 μm) HPLC Columns

L × I.D. 15 cm × 4.6 mm, HPLC Column

别名:

核壳(SPP)实心核C18 HPLC色谱柱

登录查看公司和协议定价

选择尺寸

0.2 MG
CN¥2,217.29
0.5 MG
CN¥3,324.19
5 X .2 MG
CN¥6,970.62

CN¥2,217.29


国内现货,预计发货时间April 14, 2025详情



选择尺寸

变更视图
0.2 MG
CN¥2,217.29
0.5 MG
CN¥3,324.19
5 X .2 MG
CN¥6,970.62

About This Item

UNSPSC代码:
41115700
eCl@ss:
32110501
NACRES:
SB.52

CN¥2,217.29


国内现货,预计发货时间April 14, 2025详情


产品名称

Ascentis® Express C18, 2.7 μm HPLC 色谱柱, 2.7 μm particle size, L × I.D. 15 cm × 4.6 mm

物料

stainless steel column

Agency

suitable for USP L1

产品线

Ascentis®

特点

endcapped

制造商/商品名称

Ascentis®

包装

1 ea of

参数

60 °C temp. range
600 bar max. pressure (9000 psi)

技术

HPLC: suitable
LC/MS: suitable
UHPLC-MS: suitable
UHPLC: suitable

长度 × 内径

15 cm × 4.6 mm

正在寻找类似产品? 访问 产品对比指南

比较类似商品

查看完整比较结果

显示差异

1 of 4

此商品
H1404SRP3027E4127
hEGF EGF, recombinant, expressed in E. coli, lyophilized powder, suitable for cell culture

E9644

hEGF

EGF human Animal-component free, recombinant, expressed in E. coli, ≥98% (SDS-PAGE), ≥98% (HPLC), suitable for cell culture

SRP3027

EGF human

recombinant

expressed in E. coli

recombinant

expressed in Baculovirus infected High-5 cells

recombinant

expressed in E. coli

recombinant

-

assay

≥97% (SDS-PAGE)

assay

>95% (SDS-PAGE)

assay

≥98% (HPLC), ≥98% (SDS-PAGE)

assay

-

technique(s)

cell culture | mammalian: suitable

technique(s)

cell culture | mammalian: suitable

technique(s)

cell culture | mammalian: suitable

technique(s)

cell culture | mammalian: suitable

Quality Level

300

Quality Level

200

Quality Level

-

Quality Level

200

form

lyophilized powder

form

lyophilized powder

form

lyophilized

form

lyophilized powder

一般描述

Ascentis Express HPLC色谱柱通过熔融核® 颗粒技术,可为您提供亚2 μm颗粒的高速度和高效率,同时保持较低的背压。高效率和低背压的结合使UPLC® (或其他超高压系统)用户及传统HPLC用户受益。
请见 Ascentis Express 主页,了解有关这项新色谱柱技术的更多信息。

法律信息

Ascentis is a registered trademark of Merck KGaA, Darmstadt, Germany
Fused-Core is a registered trademark of Advanced Materials Technology, Inc.
UPLC is a registered trademark of Waters
  • 技术规格说明书

  • 历史批次信息供参考:

    分析证书(COA)

    Lot/Batch Number

    没有发现合适的版本?

    如果您需要特殊版本,可通过批号或批次号查找具体证书。

    已有该产品?

    在文件库中查找您最近购买产品的文档。

    访问文档库

    1. Which document(s) contains shelf-life or expiration date information for a given product?

      If available for a given product, the recommended re-test date or the expiration date can be found on the Certificate of Analysis.

    2. How do I get lot-specific information or a Certificate of Analysis?

      The lot specific COA document can be found by entering the lot number above under the "Documents" section.

    3. What is special about Ascentis Express?

      Ascentis Express columns provide a breakthrough in HPLC performance. Based on Fused-Core particle technology, Ascentis Express provides the benefits of sub-2 μm particles but at much lower backpressure.  These benefits include the capability of providing fast HPLC and higher resolution chromatography.  The Fused-Core particle consists of a 1.7 μm solid core and a 0.5 μm porous shell.  A major benefit of the Fused-Core particle is the small diffusion path (0.5 μm) compared to conventional fully porous particles. The shorter diffusion path reduces axial dispersion of solutes and minimizes peak broadening.

    4. Is there anything special I need to do to my HPLC system to use Ascentis Express?

      Nothing special is required to use Ascentis Express HPLC columns.  To obtain the full benefits of Ascentis Express, one should minimize dispersion in the HPLC system (tubing, detector flow cell) as well as confirm the detector response system is set at a fast level.  For more information, request Guidelines for Optimizing Systems for Ascentis Express Columns (T407102).

    5. Can I use Ascentis Express on any type of HPLC system?

      Ascentis Express HPLC columns are capable of use on standard HPLC systems as well as UHPLC systems.  Columns are packed in high pressure hardware capable of withstanding the pressures used in UHPLC systems.

    6. Can I use Ascentis Express on a UHPLC system?

      Yes.  Ascentis Express columns are packed in a way making them suitable for these ultra high pressure instruments.  In fact, Ascentis Express outperforms sub-2 μm micron columns on many applications since Ascentis Express provides the benefits of sub-2 μm particles but at much lower back pressure.  These benefits include the capability of providing fast HPLC and higher resolution chromatography.  The Fused-Core particle consists of a 1.7 μm solid core and a 0.5 μm porous shell.  A major benefit of the Fused-Core particle is the small diffusion path (0.5 μm) compared to conventional fully porous particles. The shorter diffusion path reduces axial dispersion of solutes and minimizes peak broadening.

    7. How do I find price and availability?

      There are several ways to find pricing and availability for our products. Once you log onto our website, you will find the price and availability displayed on the product detail page. You can contact any of our Customer Sales and Service offices to receive a quote.  USA customers:  1-800-325-3010 or view local office numbers.

    8. What is the Department of Transportation shipping information for this product?

      Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product. 

    9. How can I measure my instrument bandwidth (IBW) and determine what Ascentis® Express HPLC Columns can be used with minimal efficiency loss created by too much internal instrument volume?

      The Guide to Dispersion Measurement has simple instructions on how to measure IBW and can be found at sigma-aldrich.com/express.

    10. Do I need special fittings and tubing to connect Ascentis® Express HPLC Columns?

      While operating pressures may not exceed the 400 bar (6,000 psi) capability of your traditional instruments, sustained pressures of about 200 bar (3,000 psi) will exceed the recommended pressure for conventional PEEK tubing and fittings at the column inlet. We recommend changing to stainless steel fittings in all high pressure locations and have designed special High Performance HPLC Fittings/Interconnects that will stay tight at pressures of 1,000 bar (15,000 psi) or greater, even when elevated column temperatures are employed.

    11. What flow rate should I use with Ascentis® Express HPLC Columns?

      Based on the minimum in the van Deemter curves, higher flows than 5um particle columns are required in order to maximize Ascentis Express column efficiency. The suggested starting point for flow rate for Ascentis Express columns: 1.6 mL/min for 4.6 mm ID;  0.8 mL/min for 3.0 mm ID; and 0.4mL/min for 2.1 mm ID.

    12. Can Ascentis® Express HPLC Columns be used for LC-MS?

      Express Fused-Core particles were designed with LC-MS in mind. Even extremely short column lengths exhibit sufficient plate counts to show high resolving power. The flat van Deemter plots permit resolution to be maintained at very high flow rates to maximize sample throughput. All Ascentis stationary phases have been evaluated for MS compatibility during their development, and the Express phases are no exception. You can expect extremely low column bleed and background while maintaining longest possible column lifetime. A bonus of Ascentis Express columns for high throughput UHPLC and LC-MS is that they are extremely rugged and highly resistant to plugging, a very common failure mode for competitor columns.

    13. What is the carbon load for Ascentis® Express C18 HPLC Columns?

      Carbon load which is commonly referred to as %Carbon is misleading and not meaningful for Ascentis® Express. Since Fused-Core particle is unique in the sense that it has a solid core and porous shell, the %Carbon number can not be compared to traditional porous particles.  The carbon coverage for Ascentis® Express C18 is 3.5 micromoles/meter-squared

    14. My question is not addressed here, how can I contact Technical Service for assistance?

      Ask a Scientist here.

    Determination of the metabolite content of Brassica juncea cultivars by comprehensive two-dimensional liquid chromatography coupled to photodiode array and mass spectrometry detection
    Arena K, et al.
    Molecules (Basel), 25(5), 1235-1235 (2020)
    Chemical characterization of three accessions of Brassica juncea L. extracts from different plant tissues
    Oulad El Majdoub Y, et al.
    Molecules (Basel), 25(22), 5421-5421 (2020)
    Yong Foo Wong et al.
    Electrophoresis (2018-02-08)
    Metabolic profiling of Glycyrrhiza glabra using comprehensive two-dimensional liquid chromatography (LC × LC) coupled with photodiode array (PDA) and mass spectrometry (MS) detection is described. The separation was conducted under reversed-phase conditions, using a combination of first dimension (1 D) 150 mm microbore
    Anna Różańska et al.
    Foods (Basel, Switzerland), 9(8) (2020-08-23)
    High quality extra virgin olive oils represent an optimal source of nutraceuticals. The European Union (EU) is the world's leading olive oil producer, with the Mediterranean region as the main contributor. This makes the EU the greatest exporter and consumer
    Katia Arena et al.
    Journal of separation science, 43(9-10), 1781-1789 (2020-04-03)
    Olea europaea, meaning "European olive," is a small tree belonging to the family Oleaceae, occurring in the Mediterranean Basin. Olive oil is an essential component of a balanced diet because of its nutritional value. Among micronutrients, phenolic compounds did show important beneficial effects for human health.

    商品

    USP methods continuously revised for modernization and improved results in drug testing.

    Optimize HPLC method for ginsenoside separation using a mixture, applying it to American Ginseng root, with conditions and chromatograms shown.

    Derivatization of Aliphatic Amines - Results from the Supelco Ascentis Express column show higher peak resolution, and improved peak shapes than typical chromatograms.

    实验方案

    Lopinavir assay setup saves time and improves efficiency with shorter columns, meeting European pharmacopoeia guidelines.

    Investigate bile acid roles in gut hormone profiles and glycemic control, vital for clinical labs exploring potential mechanisms.

    -methylcarbamate 10 μg/mL; Diuron; Propham; Siduron; Methiocarb, analytical standard; Linuron 10 μg/mL; Swep 10 μg/mL; Chlorpropham 10 μg/mL; Barban; Neburon

    相关内容

    Ibuprofen and impurity separation using Ascentis Express 90Å C18 column with excellent peak shape and low quantification limits.

    Bile Acids (BA) are synthesized in the liver and play important roles in cholesterol homeostasis, absorption of vitamins and lipids, and various key metabolic processes.

    Accurately detect and quantify trace nitrosamines (NDMA, NDEA, NEIPA, NDIPA, NDBA, etc.) in pharmaceutical drugs using our complete product portfolio and application guides for LC-MS and GC-MS. Order high-quality reference standards, columns, filters & more.

    Chromatograms

    application for HPLCapplication for HPLCapplication for HPLCapplication for HPLC展开

    我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

    联系客户支持