产品名称
Optiseal Durapore 筒式过滤器 0.22 µm 疏水性, OptiSeal® 4 in., pore size 0.22 μm, filtration area 0.18 m2, matrix Durapore®
material
PVDF
polypropylene
polypropylene support
silicone seal
sterility
non-sterile
sterilization compatibility
steam-in-place compatible
steam-in-place compatible
product line
OptiSeal® 4 in.
feature
hydrophobic
manufacturer/tradename
OptiSeal®
parameter
≤2 mL/min nitrogen diffusion at 1.0 bar (15 psig) and 23 °C (in 60/40% IPA/water)
0.35 bar max. differential pressure (5 psid) at 121 °C (Forward)
0.35 bar max. inlet pressure (5 psi) at 135 °C (Forward)
3.5 bar max. differential pressure (50 psid) at 25 °C (Reverse)
3.5 bar max. differential pressure (50 psid) at 80 °C (Forward)
3.5 bar max. inlet pressure (50 psi) at 25 °C (Reverse)
3.5 bar max. inlet pressure (50 psi) at 80 °C (Forward)
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 25 °C (Forward)
technique(s)
sterile filtration: suitable
L
4 in.
cartridge nominal length
4 in. (10 cm)
filtration area
0.18 m2
impurities
≤0.5 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.5 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
gravimetric extractables
≤10 mg/cartridge
matrix
Durapore®
pore size
0.22 μm pore size
input
sample type liquid
bubble point
≥1240 mbar (18 psig), nitrogen with 60/40% IPA/water at 23 °C
cartridge code
not applicable
Quality Level
Analysis Note
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
General description
Other Notes
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer Wetting Instructions for Filter Units with Durapore® Membrane user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
Packaging
Preparation Note
30 SIP cycles of 30 min @ 135 °C; 10 autoclave cycles of 30 min @ 126 °C