产品名称
Opticap XL 150 Millipore Express PHF 可γ辐照 0.2 µm 9/16 in.HB/HB, Chemistry: Hydrophilic Polyethersulfone (PES)Inlet: 9/16 in. Hose Barb Outlet: 9/16 in. Hose BarbMax Operating Pressure: 80 psi @ 25 °C
feature
gamma compatible, hydrophilic
manufacturer/tradename
Millipore Express®
parameter
≤1.4 mL/min air diffusion at 2.8 bar (40 psig) and 23 °C (in water), 1.0 bar max. inlet pressure (15 psi) at 80 °C, 1000 bar max. differential pressure (15 psi) at 80 °C, 2.75 bar max. inlet pressure (40 psi) at 60 °C, 25 °C max. inlet temp., 5.5 bar max. inlet pressure (80 psi) at 25 °C, 5500 mbar max. differential pressure (80 psi) at 25 °C, 80 psig max. inlet pressure
technique(s)
bioburden reduction: suitable
L
9.7 cm (3.8 in.)
W
2.2 in.
cartridge nominal length
3.8 in. (9.7 cm)
diam.
5.6 cm (2.2 in.)
filtration area
220 cm2
inlet connection diam.
9/16 in.
inlet to outlet W
9.7 cm (3.8 in.)
outlet connection diam.
9/16 in.
impurities
≤0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction), <0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
matrix
Millipore Express® PHF
pore size
0.2 μm
fitting
1/4 in. drain/vent hose barb (with double O-ring seal), inlet hose barb, outlet hose barb, (14 mm (9/16 in.) Hose Barb Inlet and Outlet)
material
polyethersulfone , polyethylene support, polypropylene (gamma-stable), polypropylene housing, polypropylene vent cap, polysulfone , silicone seal
reg. compliance
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
Quality Level
sterility
irradiated, non-sterile
sterilization compatibility
gamma compatible
product line
Opticap® XL 150
正在寻找类似产品? 访问 产品对比指南
General description
Packaging
Preparation Note
3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
Analysis Note
Samples of membrane used in this filter were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
After sterilization and a controlled water flush of 2.0 L, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64> at 25 °C.
Other Notes
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer wetting instructions of Filters with MILLIPORE EXPRESS® Membrane user guide
- Storage Statement: Please refer Filters with MILLIPORE EXPRESS® Membrane user guide
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
Legal Information
Disclaimer
相关内容
Learn how prefilters and bioburden control can improve the efficiency of downstream purification by removing particulates and protecting unit operations.
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系客户支持