跳转至内容

尊敬的客户:

目前国际形势复杂多变,关税政策尚不明朗,这可能对我们的产品价格产生一定影响。在此情况下,我们希望就订单事宜与您进行友好沟通。

基于当前的不确定性,如果您选择在此期间下单,我们将保留根据实际情况调整价格的权利。同时,我们也理解市场变化可能给您带来的困扰,因此如果在订单实际发货前因关税政策变动导致价格出现较大波动,默克将与您进行协商讨论并视情况对订单进行调整或取消。

We are planning system maintenance between Friday, Apr 18 at 9:00 PM CDT and Saturday, Apr 19 at 9:00 AM CDT. This will impact both web and offline transactions, including online orders, quotes, price and availability checks, and order status inquiries. We apologize for any inconvenience.

关于应对近期政策变化的重要更新,请点击此处查看详情。

Merck
CN
HomeLightCycler® Probes

LightCycler® Probes

LightCycler® probes are highly sensitive and sequence-specific fluorescent probes designed for use with Roche LightCycler® instruments.

Choose LightCycler® Probes for:

  • SNP detection
  • Allele discrimination
  • Pathogen detection
  • Multiplexing
  • Viral load quantification
  • Gene expression analysis
  • Gene copy determination

Several reporters are available and are suitable for multiplex analysis.

Benefits of Using LightCycler® Probes include:

  • Increased specificity
  • Probe preserved during the reaction
  • Increased thermal stability and hybridization specificity
  • Greater accuracy in SNP detection and allele discrimination
  • Easier and more sensitive probe designs for problematic target sequences

Add Locked Nucleic Acid to Your Probe for:

  • Increased thermal stability and hybridization specificity
  • Greater accuracy in SNP detection and allele discrimination
  • Easier and more sensitive probe designs for problematic target sequences

How LightCycler® Probes Work

A LightCycler® Probe system consists of a pair of single-stranded fluorescent-labeled oligonucleotides. Oligo Probe 1 is labeled at the 3’ end with a donor reporter and Oligo Probe 2 is labeled at its 5’ end with one of a few available acceptor reporters. The free 3’ hydroxyl group of Probe 2 must be blocked with a phosphate group (P) to prevent DNA polymerase extension. There should be a space of 1 to 5 nt to separate the two probes from each other. The structures and mechanism of a LightCycler® probe are shown below.

During the annealing step of qPCR, the PCR primers and the LightCycler® Probes hybridize to their specific target regions bringing the donor dye into close proximity to the acceptor dye. When the donor dye is excited by light from the LightCycler® instrument, energy is transferred by FRET from the donor to the acceptor dye. The acceptor reporter’s emission wavelength is detected. The increase in fluorescence signal is directly proportional to the amount of target DNA.

Product Features include:

  • Amounts: 0.1, 0.25, 1.5, and 15 OD
  • Purification: HPLC
  • Sequence Lengths: 15 - 40 bases
  • Quality Control: 100% mass spectrometry
  • Format: Supplied dry in amber tubes
  • Custom formats available (normalization, special plates, etc.)

Our probes are provided in a format to simplify your experimental planning.

Guarenteed Yields

Guaranteed
OD Yield
Approx. No.
of nmoles
Approx. No.
of µg
Approx. No.
of Reactions*
0.10.43.280
0.2518200
1.56481,200
156048012,000

*Estimate is based on 4 nmoles or 32 µg for 1 OD and 200 nM in 25 µL reaction (5.0 pmol/reaction). Estimate is based on an average sequence length of 25 bases.

The recommended constructs for Oligo Probe 1 and Oligo Probe 2 are listed in the tables below:

Labels and Modifications

Oligo Probe 1
3' donor fluorophore6-FAM™
Oligo Probe 2*
3' endPhosphate
5' endLightCycler Red 610, 640, 670 and 705

*For enhanced discrimination, Locked Nucleic Acid can be incorporated into Probe 2.

Shipping Schedule

Quantity (OD)0.10.251.515
LightCycler® Probes7-10 days7-10 days7-10 days7-10 days
Locked Nucleic Acid LightCycler® Probes7-10 days7-10 days7-10 days7-10 days

*Delivery times may be longer due to international transit, customs clearance delays, etc. Large projects will be placed on a delivery schedule based upon project needs.

登录以继续。

如要继续阅读,请登录或创建帐户。

暂无帐户?