跳转至内容
Merck
CN
所有图片(1)

文件

安全信息

MSCAL5

Supelco

ProteoMass LTQ/FT-Hybrid ESI Pos. Mode Cal Mix

登录查看公司和协议定价


About This Item

UNSPSC代码:
41116107
NACRES:
NA.24

产品线

ProteoMass

质量水平

CofA

current certificate can be downloaded

包装

pkg of 1 × 10 mL

储存条件

protect from light

浓度

(varied conc.)

技术

mass spectrometry (MS): suitable

格式

multi-component solution

运输

dry ice

储存温度

−20°C

正在寻找类似产品? 访问 产品对比指南

一般描述

The ProteoMass ESI Calibration Kit for LTQ based Hybrids, positive ion mode calibration solution, enables calibration of Thermo Scientific hybrid instruments equipped with ESI source in positive ion mode. It covers a mass range from m/z 138 to m/z 1822, and is therefore usable for calibrations between m/z 50 and 2000.

应用

ProteoMass LTQ/FT-hybrid ESI Pos. mode cal mix has been used as a calibration standard for the mass spectrometric analysis of serum samples of patients affected by mugwort pollen allergy induced by pollen extract of Artemisia vulgaris.

特点和优势

Discover the Advantages for Yourself!
  • Ready-to-use
  • Developed and qualified specifically for use with the LTQ based Thermo Scientific hybrid instruments (LTQ FT, LTQ FT Ultra, and LTQ Orbitrap series) with ESI source and Thermo Scientific Exactive
  • Conveniently packaged, freeing you from time consuming mixing and dilution steps, allowing you to focus on the acquistion of quality data

法律信息

6538 is a trademark of American Type Culture Collection
ProteoMass is a trademark of Sigma-Aldrich Co. LLC

警示用语:

Danger

危险分类

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Eye Irrit. 2 - Flam. Liq. 2 - STOT SE 1

靶器官

Eyes,Central nervous system

WGK

WGK 2

闪点(°F)

42.1 °F

闪点(°C)

5.6 °C

法规信息

监管及禁止进口产品

Choose from one of the most recent versions:

分析证书(COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Robert J Strife et al.
Rapid communications in mass spectrometry : RCM, 24(11), 1497-1501 (2010-05-21)
Kendrick Mass Mapping of complex sample compositions, via data derived by Fourier transform ion cyclotron resonance mass spectrometry (FTICRMS) at 1,000,000 resolution, is becoming more common. The Orbitrap mass spectrometer (Fourier Transform Axially Harmonic Orbital Trapping) also uses FT methods
Adam P Bateman et al.
Analytical chemistry, 82(19), 8010-8016 (2010-09-03)
This work demonstrates the utility of a particle-into-liquid sampler (PILS), a technique traditionally used for identification of inorganic ions present in ambient or laboratory aerosols, for the analysis of water-soluble organic aerosol (OA) using high-resolution electrospray ionization mass spectrometry (HR-ESI-MS).
Hypoallergenic acid-sensitive modification preserves major mugwort allergen fold and delivers full repertoire of MHC class II-binding peptides during endolysosomal degradation
Stanic-Vucinic D, et al.
Royal Society of Chemistry Advances, 91(6), 88216-88228 (2016)
Toine F H Bovee et al.
Food additives & contaminants. Part A, Chemistry, analysis, control, exposure & risk assessment, 33(5), 749-759 (2016-04-20)
In 2013 the Dutch authorities issued a warning against a dietary supplement that was linked to 11 reported adverse reactions, including heart problems and in one case even a cardiac arrest. In the UK a 20-year-old woman, said to have
Adam P Bateman et al.
Physical chemistry chemical physics : PCCP, 13(26), 12199-12212 (2011-05-28)
The effect of UV irradiation on the molecular composition of aqueous extracts of secondary organic aerosol (SOA) was investigated. SOA was prepared by the dark reaction of ozone and d-limonene at 0.05-1 ppm precursor concentrations and collected with a particle-into-liquid

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门