跳转至内容
Merck
CN
所有图片(1)

主要文件

G005697

HPLC Analysis of Fat Soluble Vitamins by Normal Phase Chromatography on Ascentis® Si (25 cm Column)

application for HPLC

登录查看公司和协议定价


About This Item

技术

HPLC: suitable

试验参数

column: Ascentis Si, 15 cm x 4.6 mm I.D., 5 μm particles (581512-U)
mobile phase: [A] hexane; [B] ethyl acetate
gradient: 10 to 30% B in 10 min; held at 30% B for 2 min
flow rate: 1.0 mL/min
column temp.: 30 °C
detector: UV, 290 nm
injection: 10 μL

适用性

application for HPLC

应用

vitamins, nutraceuticals, and natural products

分析说明

Ascentis silica is used in the analysis of fat-soluble vitamins using a normal phase gradient. These include vitamin K 3 (menadione), vitamin E (alpha and gamma tocopherol), and vitamin D3 (cholecalciferol).

法律信息

Ascentis is a registered trademark of Merck KGaA, Darmstadt, Germany

分析物

说明

    (±)-α-Tocopherol, analytical standard
    Menadione (K3), analytical standard
    (+)-γ-Tocopherol, analytical standard
    Cholecalciferol (D3), analytical standard

历史批次信息供参考:

分析证书(COA)

Lot/Batch Number

抱歉,我们目前尚未线上提供该产品的COA。

如需帮助,请联系 客户支持

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门