If you decide to place an order during this period, we reserve the right to adjust the price based on the evolving situation. We understand that market changes may cause inconvenience. We will negotiate with you if there’s a significant price fluctuation due to tariff policy changes before the order’s actual delivery, and in such cases we may adjust or cancel the order as necessary.

Merck
CN
所有图片(1)

主要文件

53825-U

Supelco

Ascentis® Express 90 Å C18 (2.7 μm) HPLC Columns

L × I.D. 15 cm × 2.1 mm, HPLC Column

别名:

核壳(SPP)实心核C18 HPLC色谱柱

登录查看公司和协议定价


About This Item

UNSPSC代码:
41115700
eCl@ss:
32110501
NACRES:
SB.52

价格与库存信息目前不能提供

产品名称

Ascentis® Express C18, 2.7 μm HPLC 色谱柱, 2.7 μm particle size, L × I.D. 15 cm × 2.1 mm

物料

stainless steel column

质量水平

Agency

suitable for USP L1

产品线

Ascentis®

特点

endcapped

制造商/商品名称

Ascentis®

包装

1 ea of

参数

60 °C temp. range
600 bar max. pressure (9000 psi)

技术

HPLC: suitable
LC/MS: suitable
UHPLC-MS: suitable
UHPLC: suitable

正在寻找类似产品? 访问 产品对比指南

比较类似商品

查看完整比较结果

显示差异

1 of 4

此商品
PHR1014H0135H0888
biological source

plant (wild yam)

biological source

-

biological source

synthetic (organic)

biological source

-

assay

97.0-102.0% dry basis

assay

-

assay

≥80% (HPLC)

assay

≥98%

Gene Information

human ... ABCB1(5243), CYP3A4(1576), NR3C1(2908), SERPINA6(866)
mouse ... Abcb1a(18671), Abcb1b(18669), Ifng(15978), Nos2(18126)
rat ... Ar(24208), Nr3c1(24413)

Gene Information

human ... NR3C1(2908)

Gene Information

human ... ABCB1(5243), CYP3A4(1576), NR3C1(2908), SERPINA6(866)
mouse ... Abcb1a(18671), Abcb1b(18669), Ifng(15978), Nos2(18126)
rat ... Ar(24208), Nr3c1(24413)

Gene Information

human ... ABCB1(5243), CYP3A4(1576), NR3C1(2908), SERPINA6(866)
mouse ... Abcb1a(18671), Abcb1b(18669), Ifng(15978), Nos2(18126)
rat ... Ar(24208), Nr3c1(24413)

Quality Level

300

Quality Level

300

Quality Level

200

Quality Level

200

form

powder

form

-

form

powder

form

powder

solubility

water: soluble 0.28 g/L at 25 °C

solubility

-

solubility

ethanol: 1 mg/mL, clear

solubility

chloroform/ethanol (1:1): 50 mg/mL, clear, colorless to very faintly yellow

一般描述

Ascentis Express HPLC色谱柱通过熔融核® 颗粒技术,可为您提供亚2 μm颗粒的高速度和高效率,同时保持较低的背压。高效率和低背压的结合使UPLC® (或其他超高压系统)用户及传统HPLC用户受益。
请见 Ascentis Express 主页,了解有关这项新色谱柱技术的更多信息。

法律信息

Ascentis is a registered trademark of Merck KGaA, Darmstadt, Germany
Fused-Core is a registered trademark of Advanced Materials Technology, Inc.
UPLC is a registered trademark of Waters

储存分类代码

11 - Combustible Solids

WGK

WGK 3

闪点(°F)

Not applicable

闪点(°C)

Not applicable

  • 技术规格说明书

  • 历史批次信息供参考:

    分析证书(COA)

    Lot/Batch Number

    没有发现合适的版本?

    如果您需要特殊版本,可通过批号或批次号查找具体证书。

    已有该产品?

    在文件库中查找您最近购买产品的文档。

    访问文档库

    1. Which document(s) contains shelf-life or expiration date information for a given product?

      If available for a given product, the recommended re-test date or the expiration date can be found on the Certificate of Analysis.

    2. How do I get lot-specific information or a Certificate of Analysis?

      The lot specific COA document can be found by entering the lot number above under the "Documents" section.

    3. What is special about Ascentis Express?

      Ascentis Express columns provide a breakthrough in HPLC performance. Based on Fused-Core particle technology, Ascentis Express provides the benefits of sub-2 μm particles but at much lower backpressure.  These benefits include the capability of providing fast HPLC and higher resolution chromatography.  The Fused-Core particle consists of a 1.7 μm solid core and a 0.5 μm porous shell.  A major benefit of the Fused-Core particle is the small diffusion path (0.5 μm) compared to conventional fully porous particles. The shorter diffusion path reduces axial dispersion of solutes and minimizes peak broadening.

    4. Is there anything special I need to do to my HPLC system to use Ascentis Express?

      Nothing special is required to use Ascentis Express HPLC columns.  To obtain the full benefits of Ascentis Express, one should minimize dispersion in the HPLC system (tubing, detector flow cell) as well as confirm the detector response system is set at a fast level.  For more information, request Guidelines for Optimizing Systems for Ascentis Express Columns (T407102).

    5. Can I use Ascentis Express on any type of HPLC system?

      Ascentis Express HPLC columns are capable of use on standard HPLC systems as well as UHPLC systems.  Columns are packed in high pressure hardware capable of withstanding the pressures used in UHPLC systems.

    6. Can I use Ascentis Express on a UHPLC system?

      Yes.  Ascentis Express columns are packed in a way making them suitable for these ultra high pressure instruments.  In fact, Ascentis Express outperforms sub-2 μm micron columns on many applications since Ascentis Express provides the benefits of sub-2 μm particles but at much lower back pressure.  These benefits include the capability of providing fast HPLC and higher resolution chromatography.  The Fused-Core particle consists of a 1.7 μm solid core and a 0.5 μm porous shell.  A major benefit of the Fused-Core particle is the small diffusion path (0.5 μm) compared to conventional fully porous particles. The shorter diffusion path reduces axial dispersion of solutes and minimizes peak broadening.

    7. How do I find price and availability?

      There are several ways to find pricing and availability for our products. Once you log onto our website, you will find the price and availability displayed on the product detail page. You can contact any of our Customer Sales and Service offices to receive a quote.  USA customers:  1-800-325-3010 or view local office numbers.

    8. What is the Department of Transportation shipping information for this product?

      Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product. 

    9. How can I measure my instrument bandwidth (IBW) and determine what Ascentis® Express HPLC Columns can be used with minimal efficiency loss created by too much internal instrument volume?

      The Guide to Dispersion Measurement has simple instructions on how to measure IBW and can be found at sigma-aldrich.com/express.

    10. Do I need special fittings and tubing to connect Ascentis® Express HPLC Columns?

      While operating pressures may not exceed the 400 bar (6,000 psi) capability of your traditional instruments, sustained pressures of about 200 bar (3,000 psi) will exceed the recommended pressure for conventional PEEK tubing and fittings at the column inlet. We recommend changing to stainless steel fittings in all high pressure locations and have designed special High Performance HPLC Fittings/Interconnects that will stay tight at pressures of 1,000 bar (15,000 psi) or greater, even when elevated column temperatures are employed.

    11. What flow rate should I use with Ascentis® Express HPLC Columns?

      Based on the minimum in the van Deemter curves, higher flows than 5um particle columns are required in order to maximize Ascentis Express column efficiency. The suggested starting point for flow rate for Ascentis Express columns: 1.6 mL/min for 4.6 mm ID;  0.8 mL/min for 3.0 mm ID; and 0.4mL/min for 2.1 mm ID.

    12. Can Ascentis® Express HPLC Columns be used for LC-MS?

      Express Fused-Core particles were designed with LC-MS in mind. Even extremely short column lengths exhibit sufficient plate counts to show high resolving power. The flat van Deemter plots permit resolution to be maintained at very high flow rates to maximize sample throughput. All Ascentis stationary phases have been evaluated for MS compatibility during their development, and the Express phases are no exception. You can expect extremely low column bleed and background while maintaining longest possible column lifetime. A bonus of Ascentis Express columns for high throughput UHPLC and LC-MS is that they are extremely rugged and highly resistant to plugging, a very common failure mode for competitor columns.

    13. What is the carbon load for Ascentis® Express C18 HPLC Columns?

      Carbon load which is commonly referred to as %Carbon is misleading and not meaningful for Ascentis® Express. Since Fused-Core particle is unique in the sense that it has a solid core and porous shell, the %Carbon number can not be compared to traditional porous particles.  The carbon coverage for Ascentis® Express C18 is 3.5 micromoles/meter-squared

    14. My question is not addressed here, how can I contact Technical Service for assistance?

      Ask a Scientist here.

    Pankaj Partani et al.
    Journal of chromatographic science, 54(8), 1385-1396 (2016-05-27)
    A liquid chromatography-tandem mass spectrometry method was developed and validated for the simultaneous determination of simvastatin (SV) and simvastatin acid (SVA) in human plasma. To improve assay sensitivity and achieve simultaneous analysis, SVA monitored in (-)ESI (electrospray ionization) mode within
    Judy Stone
    Methods in molecular biology (Clifton, N.J.), 1378, 301-320 (2015-11-26)
    Serum from bar-coded tubes, and then internal standard, are pipetted to 96-well plates with an 8-channel automated liquid handler (ALH). The first precipitation reagent (methanol:ZnSO4) is added and mixed with the 8-channel ALH. A second protein precipitating agent, 1 %
    Babu Rao Chandu et al.
    SpringerPlus, 2(1), 194-194 (2013-06-07)
    A bioequivalence study was proved of generic Febuxostat 80 mg tablets (T) in healthy volunteers.For this purpose, Authors developed a simple, sensitive, selective, rapid, rugged and reproducible liquid chromatography-tandem mass spectrometry method for the quantification of Febuxostat (FB) in human
    Silvia Jakabová et al.
    Journal of chromatography. A, 1232, 295-301 (2012-03-07)
    Hyoscyamine (atropine) and scopolamine are the predominant tropane alkaloids in the Datura genus, occurring in all plant organs. The assessment of the alkaloid content of various plant parts is essential from the viewpoint of medical use, but also as a
    Virginia Brighenti et al.
    Journal of pharmaceutical and biomedical analysis, 143, 228-236 (2017-06-14)
    The present work was aimed at the development and validation of a new, efficient and reliable technique for the analysis of the main non-psychoactive cannabinoids in fibre-type Cannabis sativa L. (hemp) inflorescences belonging to different varieties. This study was designed

    商品

    Supel Tox AflaZea SPE improves analyte recovery with less sample volume, while HPLC confirms effective elimination of interferences.

    Derivatization of Aliphatic Amines - Results from the Supelco Ascentis Express column show higher peak resolution, and improved peak shapes than typical chromatograms.

    实验方案

    This selective and fast MIP extraction procedure allows trace amounts of patulin to be easily detected in apple juice, with high analyte recovery and reproducibility.

    Chromatograms

    application for HPLCapplication for HPLC

    我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

    联系客户支持