25320-U

Supelco

VOCOL® 毛细管GC色谱柱

L × I.D. 30 m × 0.53 mm, df 3.00 μm

别名:

熔融石英毛细管,VOCOL®,30m×0.53mm,3.0μm(不混合)

登录查看公司和协议定价


About This Item

UNSPSC代码:
77101502
eCl@ss:
32119290
NACRES:
SB.54

物料

fused silica

质量水平

Agency

EPA TO-17,502.2,624,8015,8260,OLM04.2 VOA,524.2
NIOSH 1003

参数

≤25-230 °C temperature (isothermal or programmed)

β值

44

df

3.00 μm

技术

gas chromatography (GC): suitable

长度 × 内径

30 m × 0.53 mm

应用

environmental
food and beverages
forensics and toxicology
industrial hygiene

色谱柱类型

capillary intermediate polar

正在寻找类似产品? 访问 产品对比指南

一般描述

Capillary GC column is also known as open tubular column. The carrier gas flows through the central aperture and is unrestricted throughout the length of the column.
应用:这种被设计用于挥发性有机化合物(VOC)分析的中间极性色谱柱可为高挥发性化合物提供较高的保留时间和分辨率。可直接通过进样端口或偶联至吹扫捕集系统而使用该色谱柱。
USP代码:非

  • 结合
  • 永久
温度。限制
  • ≤0.32 mm I.D., <2 μm: 亚常温至250 °C (等温或程序性的)
  • ≤0.32 mm I.D., ≥2 μm: 亚常温至230 °C (等温或程序性的)
  • ≥0.53 mm I.D., <2 μm: 亚常温至250 °C (等温或程序性的)
  • ≥0.53 mm I.D., ≥2 μm: 亚常温至230 °C (等温或程序性的)

应用

VOCOL® column (diphenyl dimethyl polysiloxane with crosslinking moieties) may be used for their relevancy to the purge-and-trap technique and GC/MS analysis of 34 volatile organics. It was also found suitable in being used for determination of volatile compounds by whole column cryotrapping.

其他说明

We offer a variety of chromatography accessories including analytical syringes

法律信息

VOCOL is a registered trademark of Merck KGaA, Darmstadt, Germany

法规信息

新产品

从最新的版本中选择一种:

分析证书(COA)

Lot/Batch Number

没有发现合适的版本?

如果您需要特殊版本,可通过批号或批次号查找具体证书。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Synthesis of monodisperse poly(divinylbenzene) microspheres
Li K and Stover HDH
Journal of Polymer Science Part A: Polymer Chemistry, 31, 3257-3263 null
Highly conductive non aqueous polymer gel electrolytes containing ammonium hexafluorophosphate (NH4PF6).
Sharma JP and Sekhon SS
J. Mater. Sci., 41(12), 3617-3622 (2006)
Anne Rosing-Schow et al.
Logopedics, phoniatrics, vocology, 35(4), 166-168 (2010-10-12)
VoiceRelease is a progressively structured treatment system that aims to release the voice through muscle tension reduction by manual therapy, thereby facilitating healthy voice production. The VoiceRelease treatment should closely interact with functional voice training and should therefore be carried
Svante Granqvist et al.
Logopedics, phoniatrics, vocology, 40(3), 113-121 (2014-05-29)
Phonation into glass tubes ('resonance tubes'), keeping the free end of the tube in water, has been a frequently used voice therapy method in Finland and more recently also in other countries. The purpose of this exploratory study was to
Ben Barsties et al.
Logopedics, phoniatrics, vocology, 41(1), 27-32 (2014-08-05)
The aim of the study was to determine the impact of body height on speaking fundamental frequency (SF0) while controlling for as many as possible influencing factors such as habits, biophysical conditions, medication, diseases, and others. Fifty-eight females were analyzed

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门