推荐产品
物料
fused silica
质量水平
Agency
meets requirements for USP G5
参数
≤25-250 °C temperature (isothermal or programmed)
β值
400
df
0.20 μm
技术
gas chromatography (GC): suitable
长度 × 内径
60 m × 0.32 mm
基质活性基团
Non-bonded; poly(biscyanopropyl siloxane) phase
色谱柱类型
capillary highly polar
正在寻找类似产品? 访问 产品对比指南
一般描述
应用:该非键合色谱柱具有同类中最高的极性。与所有通用双氰丙基丙基色谱柱一样,它可在高温和低温下非常有效的分离脂肪酸甲酯(FAME)、二恶英、碳水化合物和芳族化合物的几何异构体。
USP 代码 :该柱符合 USP G5 要求。
相:
USP 代码 :该柱符合 USP G5 要求。
相:
- 非键合
- 聚(双氰丙基硅氧烷)
- 常温至 250°C(等温或程序升温)
SP®-2340 is a cyanopropylsiloxane stationary phase, and has high polarity and temperature resistance.
应用
Capillary column coated with SP®-2340 stationary phase may be used in gas chromatographic analysis and separation of cis/trans isomeric fatty acids.
其他说明
We offer a variety of chromatography accessories including analytical syringes
法律信息
SP is a registered trademark of Sigma-Aldrich Co. LLC
法规信息
新产品
SP 2340 in the glass capillary chromatography of fatty acid methyl esters.
Journal of Chromatography A, 136 (2), 311-317 (1977)
Journal of chromatography. A, 1081(2), 248-254 (2005-07-26)
The solvation parameter model is used to characterize the retention properties of the bis(cyanopropylsiloxane)-co-methylsilarylene, HP-88, and poly(siloxane), Rtx-440, stationary phases over the temperature range 60-140 degrees C. HP-88 is among the most cohesive, dipolar/polarizable and hydrogen-bond basic of stationary phases
Journal of chromatography. A, 912(1), 107-117 (2001-04-20)
The solvation parameter model is used to study the influence of temperature and composition on the selectivity of nine poly(siloxane) and two poly(ethylene glycol) stationary phase chemistries for open-tubular column gas chromatography. A database of system constants for the temperature
Journal - Association of Official Analytical Chemists, 70(4), 702-705 (1987-07-01)
A method has been developed for the quantitative determination of linoleic acid in infant formulas by gas chromatography (GC). A known amount of triheptadecanoin was spiked into the sample. Total lipid was extracted from the product by an ethyl ether-petroleum
Journal of separation science, 30(5), 740-745 (2007-04-28)
The solvation parameter model is used to characterize the separation properties of the polar stationary phases EC-Wax and PAG with a poly(ethylene oxide) backbone (substituted with propylene oxide in the case of PAG) and the cyanopropyl-substituted polysilphenylene-siloxane stationary phase BPX90
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门