跳转至内容

尊敬的客户:

目前国际形势复杂多变,关税政策尚不明朗,这可能对我们的产品价格产生一定影响。在此情况下,我们希望就订单事宜与您进行友好沟通。

基于当前的不确定性,如果您选择在此期间下单,我们将保留根据实际情况调整价格的权利。同时,我们也理解市场变化可能给您带来的困扰,因此如果在订单实际发货前因关税政策变动导致价格出现较大波动,默克将与您进行协商讨论并视情况对订单进行调整或取消。

Merck
CN
所有图片(1)

主要文件

安全信息

2048505

Supelco

进样口衬管,不分流,具有双锥部

pkg of 5 ea

登录查看公司和协议定价

选择尺寸

100 μL
¥5,551.31

¥5,551.31


请联系客服了解存货情况

获取大包装报价

选择尺寸

变更视图
100 μL
¥5,551.31

About This Item

UNSPSC代码:
41121800

¥5,551.31


请联系客服了解存货情况

获取大包装报价

包装

pkg of 5 ea

长度 × 外径 × 内径

78.5 mm × 6.5 mm × 4.0 mm

正在寻找类似产品? 访问 产品对比指南

比较类似商品

查看完整比较结果

显示差异

1 of 4

此商品
PHR1533C8503C8667
胆固醇 powder, BioReagent, suitable for cell culture, ≥99%

C3045

胆固醇

胆固醇 Pharmaceutical Secondary Standard; Certified Reference Material

PHR1533

胆固醇

胆固醇 from sheep wool, ≥92.5% (GC), powder

C8503

胆固醇

胆固醇 Sigma Grade, ≥99%

C8667

胆固醇

technique(s)

cell culture | mammalian: suitable

technique(s)

HPLC: suitable, gas chromatography (GC): suitable

technique(s)

-

technique(s)

-

assay

≥99%

assay

-

assay

≥92.5% (GC)

assay

≥99%

biological source

ovine wool

biological source

-

biological source

sheep wool

biological source

sheep wool

solubility

H2O: 0.002 mg/mL, ethanol: soluble, Tween: soluble, serum: soluble

solubility

water: soluble 0.00003 g/L at 20 °C

solubility

water: soluble 0.00003 g/L at 20 °C

solubility

water: soluble 0.00003 g/L at 20 °C

form

powder

form

powder

form

powder

form

powder

storage temp.

−20°C

storage temp.

-10 to -25°C

storage temp.

room temp

storage temp.

−20°C

一般描述

Deactivated (silanized) glass inlet liner for capillary injection ports.
  • Fits Agilent (5890, 6890, and 7890)
  • Fits Finnigan (9001GCQ)
  • Fits Varian (CP-1177 Injector)
The liner is the second most important part of the inlet. It is the centrepiece of the inlet system, basically a glass tube between the septum and the column, where the sample is evaporated and brought into the gas phase. Split/splitless inlet allows fast sample introduction and vaporization which is highly advantageous for small sample sizes. Though the injection modes for both split and splitless are carried out on the same inlet, there are certain differences like a splitless injection involves the complete introduction of the sample into the column whereas in a split injection, the sample is divided in the inlet as a result only part of the sample is introduced in the column.[1]

法规信息

新产品
  • 技术规格说明书

  • 历史批次信息供参考:

    分析证书(COA)

    Lot/Batch Number

    It looks like we've run into a problem, but you can still download Certificates of Analysis from our 文件 section.

    如需帮助,请联系 客户支持

    已有该产品?

    在文件库中查找您最近购买产品的文档。

    访问文档库

    Els Van Hoeck et al.
    Journal of chromatography. A, 1157(1-2), 1-9 (2007-05-08)
    Stir bar sorptive extraction (SBSE) was applied to the enrichment of pyrethroids in water samples. Analysis was done by retention time-locked GC/MS in selected ion-monitoring (SIM) mode using trans-permethrin-d(6) as internal standard. Thermal desorption (TD) was performed in a classical
    Fire Debris Analysis.
    Stauffer E
    Science, 249-252 (2007)

    商品

    Complete workflow for cannabis flower pesticide testing using LC-MS/MS and GC-MS/MS ensures product safety.

    我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

    联系客户支持