product name
分子筛吸附剂, matrix Molecular Sieve 5A, 60-80 mesh, bottle of 50 g
Agency
suitable for USP/NF nitrogen
质量水平
形式
solid
包装
bottle of 50 g
基质
Molecular Sieve 5A
粒径
60-80 mesh
孔径
5 Å pore diameter
密度
~0.72 g/mL (free fall density)
正在寻找类似产品? 访问 产品对比指南
一般描述
有关我们的吸附剂的更多信息,请访问 sigma-aldrich.com/adsorbents
警示用语:
Warning
危险声明
预防措施声明
危险分类
STOT RE 2 Inhalation
靶器官
Lungs
WGK
nwg
闪点(°F)
Not applicable
闪点(°C)
Not applicable
个人防护装备
Eyeshields, Gloves, type N95 (US)
Choose from one of the most recent versions:
分析证书(COA)
Don't see the Right Version?
If you require a particular version, you can look up a specific certificate by the Lot or Batch number.
Which document(s) contains shelf-life or expiration date information for a given product?
If available for a given product, the recommended re-test date or the expiration date can be found on the Certificate of Analysis.
How do I get lot-specific information or a Certificate of Analysis?
The lot specific COA document can be found by entering the lot number above under the "Documents" section.
How do you condition Molecular Sieve 5A, Product 20302, when used in a packed column?
Attach the column to your GC injection port, establish a flow rate of at least 25 mL/min carrier gas, purge with carrier gas at room temperature for 30 minutes, increase oven temperature to 225°C at a rate of 4°C/min, and allow the column to condition at 225°C for 8-12 hours. After conditioning, allow the oven to cool to room temperature, turn off the carrier flow and allow the pressure to go to zero. Then reinstall the column into both the injector port and detector port, and establish desired carrier flow rate. The column should then be ready to use.
What does 5A refer to in Molecular Sieve 5A, Product 20302?
5A is a grade of Mol Sieve and refers to a nominal pore size of 5 Angstroms
How is Supelco's Molecular Sieve 5A, Product No. 20302, commonly used?
Mol Sieve 5A is commonly packed in columns for the analysis of permanent gases via Gas Chromatography.
Is this product a packed column?
This is packing material only; it is not a column. Some endusers will purchase this bottle of packing and prepare their own packed columns.
How can I purchase a column that is packed with this material?
Most packed column are custom made and require that you obtain a quotation. Please contact our Customer & Sales Services group at phone number (800)-247-6628, fax number (800)-447-3044 or email CIBelle@sial.com for additional information.
How do I find price and availability?
There are several ways to find pricing and availability for our products. Once you log onto our website, you will find the price and availability displayed on the product detail page. You can contact any of our Customer Sales and Service offices to receive a quote. USA customers: 1-800-325-3010 or view local office numbers.
What is the Department of Transportation shipping information for this product?
Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.
What is the maximum temperature for this packing?
The maximum temperature for this packing is 400 °C.
What does the 60/80 stand for in the product description?
The 60/80 refers to the mesh size range of the actual particles. When working with mesh size: the larger the mesh number, the smaller the diameter of the particle. In this case 60 refers to a diameter of 250 microns and 80 refers to a diameter of 177 microns. Therefore; the particles in this product with 60/80 will range between 177 microns and 250 microns.
My question is not addressed here, how can I contact Technical Service for assistance?