推荐产品
物料
W,W,W separators
质量水平
Agency
EPA TO-15
OSHA 52,61
产品线
Amberlite™
ORBO™
组成
Bed A, 150 mg
Bed B, 75 mg
包装
pkg of 25 ea
制造商/商品名称
ORBO™ 24
技术
active air sampling: suitable
外径 × 长度
6 mm × 105 mm
基质
XAD-2 2-(Hydroxymethyl)piperidine (2-HMP) on XAD-2
粒径
20-40 mesh
应用
air monitoring
environmental
industrial hygiene
储存温度
2-8°C
正在寻找类似产品? 访问 产品对比指南
法律信息
Amberlite is a trademark of DuPont de Nemours, Inc.
ORBO is a trademark of Sigma-Aldrich Co. LLC
Supelpak is a trademark of Sigma-Aldrich Co. LLC
XAD is a registered trademark of The Dow Chemical Company or an affiliated company of Dow
未找到合适的产品?
试试我们的产品选型工具.
警示用语:
Danger
危险声明
危险分类
Eye Dam. 1 - Skin Corr. 1B
储存分类代码
8A - Combustible corrosive hazardous materials
WGK
WGK 3
个人防护装备
Eyeshields, Gloves, type N95 (US)
Journal of AOAC International, 80(5), 1091-1097 (1997-11-05)
A method to sample and analyze chlorothalonil and dichlofluanid in greenhouse air was evaluated. Analysis was performed by gas chromatography with electron capture detection and gas chromatography-mass spectrometry. Solid sorbents such as Chromosorb 102, Porapak R, Supelpak-2, Amberlite XAD-2, Amberlite
Journal of chemical ecology, 17(11), 2127-2141 (1991-11-01)
Male American palm weevils (APWs),Rhynchophorus palmarum (L.) produced two sex-specific compounds, which were disclosed by volatile collections on Supelpak-2 and gas chromatography. One was a minor compound, not always detected. The major male-produced volatile was identified as (2E)-6-methyl-2-hepten-4-ol through coupled
Analytica chimica acta, 573-574, 209-215 (2007-08-29)
A methodology is described for greenhouse air analysis by sampling fenhexamid, pyrimethanil, malathion, metalaxyl-M and myclobutanil in solid sorbents. Pesticides were determined by gas chromatography with NP Detector. The trapping efficiency of XAD-2, XAD-4, Supelpak-2, Florisil and C-18 at different
Anticancer research, 29(4), 1047-1052 (2009-05-06)
Endometrial hyperplasia is a precursor lesion of endometrial carcinoma. Clinical studies of endometrial hyperplasia have shown that levonorgestrel (LNG) is more therapeutically effective than medroxyprogesterone acetate (MPA). The present pharmacological in vitro study was performed to compare progestin effects on
Scandinavian journal of clinical and laboratory investigation, 55(8), 715-721 (1995-12-01)
Elevated extracellular cGMP levels have been observed in various clinical conditions, and the analyte has been proposed as a diagnostic marker of cardiovascular as well as malignant diseases. However, the use of extracellular cGMP as a pathophysiological marker requires detailed
Chromatograms
suitable for GC, application for air monitoring我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门