推荐产品
描述
cationic
质量水平
方案
≥99.0% (AT)
表单
crystals
质量
LiChropur™
技术
ion pair chromatography: suitable
mp
99-100 °C (lit.)
λ
10 % in methanol
紫外吸收
λ: 240 nm Amax: 0.06
λ: 250 nm Amax: 0.04
λ: 260 nm Amax: 0.03
λ: 500 nm Amax: 0.03
适用性
corresponds to standard for filter test
SMILES字符串
[Br-].CCCCCC[N+](CCCCCC)(CCCCCC)CCCCCC
InChI
1S/C24H52N.BrH/c1-5-9-13-17-21-25(22-18-14-10-6-2,23-19-15-11-7-3)24-20-16-12-8-4;/h5-24H2,1-4H3;1H/q+1;/p-1
InChI key
SYZCZDCAEVUSPM-UHFFFAOYSA-M
正在寻找类似产品? 访问 产品对比指南
一般描述
The utilization of ion-pairing reagents as mobile phase additives allows the elution of ionic and highly polar substances using reversed phase HPLC columns. The purity of mobile phase additives is a prime factor to their successful application. Sigma-Aldrich offers an outstanding collection of tailor-made reagents for anionic (quaternary ammonium and phosphonium salts) and cationic (alkanesulfonates) analyzes. All mobile phase additives are rigorously tested with special emphasis on the requirements of modern reversed phase HPLC:
法律信息
LiChropur is a trademark of Merck KGaA, Darmstadt, Germany
储存分类代码
11 - Combustible Solids
WGK
WGK 3
闪点(°F)
Not applicable
闪点(°C)
Not applicable
个人防护装备
dust mask type N95 (US), Eyeshields, Gloves
The effects of tetrahexylammonium chloride on calcium mobilization from cerebellar microsomes.
Biochemical Society transactions, 21(2), 105S-105S (1993-05-01)
Journal of controlled release : official journal of the Controlled Release Society, 116(1), 50-57 (2006-10-20)
Parallel Artificial Membrane Permeability Assay (PAMPA) is a method to screen drug candidates for membrane permeability. The objective was to characterize the transport of a model weak base, metoprolol, across a three lipid-component PAMPA system (denoted A-PAMPA, for anionic-PAMPA) and
Journal of the American Chemical Society, 126(9), 2939-2943 (2004-03-05)
Resorcinarene 1b forms a hexameric assembly in water-saturated CDCl(3) that encapsulates one tetraalkylammonium salt (2(+)Br(-)). The remaining space is occupied by coencapsulated solvent molecules. A maximum of three and minimum of one CHCl(3) molecule were found inside of capsules with
Journal of lipid research, 8(1), 55-58 (1967-01-01)
Ethyl acetate or chloroform solutions of tetraheptylammonium chloride, an oil-soluble quaternary amine, quantitatively extract polar, anionic lipids such as steroid or bile salt conjugates from aqueous solution by a process of anion exchange.
Biochimica et biophysica acta, 1152(1), 177-183 (1993-10-10)
In this study we show that the potassium-channel blocker tetrahexyl ammonium chloride (THA+) is able to inhibit inositol 1,4,5-trisphosphate (InsP3)-induced calcium release in an apparently biphasic fashion with a IC50 of 3 microM. This inhibition was not alleviated by valinomycin
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门