跳转至内容
Merck
CN

O2706

Sigma-Aldrich

八氟甲苯

98%

登录查看公司和协议定价

别名:
全氟甲苯
线性分子式:
C6F5CF3
CAS号:
分子量:
236.06
Beilstein:
2057072
EC 号:
MDL编号:
UNSPSC代码:
12352100
PubChem化学物质编号:
NACRES:
NA.22

质量水平

检测方案

98%

折射率

n20/D 1.368 (lit.)

bp

104 °C (lit.)

密度

1.666 g/mL at 25 °C (lit.)

SMILES字符串

Fc1c(F)c(F)c(c(F)c1F)C(F)(F)F

InChI

1S/C7F8/c8-2-1(7(13,14)15)3(9)5(11)6(12)4(2)10

InChI key

USPWUOFNOTUBAD-UHFFFAOYSA-N

正在寻找类似产品? 访问 产品对比指南

象形图

FlameSkull and crossbones

警示用语:

Danger

危险声明

危险分类

Acute Tox. 3 Inhalation - Acute Tox. 4 Oral - Flam. Liq. 2

WGK

WGK 3

闪点(°F)

68.0 °F

闪点(°C)

20 °C

个人防护装备

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter

法规信息

新产品

分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

M H Baker et al.
Biomedical & environmental mass spectrometry, 16(1-12), 211-213 (1988-10-01)
The use of octafluorotoluene (OFT) as a versatile gas chromatographic/mass spectrometric derivatizing agent for steroids containing alcoholic, phenolic or alpha, beta-unsaturated keto functions, is described. Two distinct derivatizing schemes can be utilized, involving (method 1) a phase-transfer reaction, employing a
Alexander V Belyakov et al.
The journal of physical chemistry. A, 124(49), 10216-10224 (2020-11-18)
The equilibrium molecular structure of the gaseous fluorofullerene C60F36 has been determined for the first time by the electron diffraction method with the use of quantum chemical calculations up to the RI-MP2/def2-TZVPP level of theory. Vibrational amplitudes and quadratic and
Z Fang et al.
Anesthesia and analgesia, 83(5), 1097-1104 (1996-11-01)
We examined the anesthetic and convulsant properties of 16 unfluorinated to completely fluorinated aromatic compounds, having six to nine carbon atoms (e.g., benzene to 1,3,5-tris(trifluoromethyl)benzene), and four cycloalkanes (cyclopentane to cyclooctane). Benzene, fluorobenzene, toluene, p-xylene, ethylbenzene, and cyclopentane caused excitation
Naohide Shinohara et al.
International journal of environmental research and public health, 7(9), 3348-3358 (2010-10-16)
A modified procedure was developed for the measurement of the effective air exchange rate, which represents the relationship between the pollutants emitted from indoor sources and the residents' level of exposure, by placing the dosers of tracer gas at locations
Philipp Lehner et al.
PloS one, 10(6), e0128125-e0128125 (2015-06-02)
Most commercially available optical oxygen sensors target the measuring range of 300 to 2 μmol L-1. However these are not suitable for investigating the nanomolar range which is relevant for many important environmental situations. We therefore developed a miniaturized phase

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门