跳转至内容
Merck
CN

H1006

Sigma-Aldrich

七氟丁酸酐

≥98%

别名:

HFAA, HFBA, 全氟丁酸酐

登录查看公司和协议定价


About This Item

线性分子式:
(CF3CF2CF2CO)2O
CAS号:
分子量:
410.06
Beilstein:
856036
EC 号:
MDL编号:
UNSPSC代码:
12352100
PubChem化学物质编号:
NACRES:
NA.22

质量水平

方案

≥98%

表单

liquid

折射率

n20/D 1.287 (lit.)

沸点

108-110 °C (lit.)

mp

−43 °C (lit.)

密度

1.674 g/mL at 20 °C (lit.)

储存温度

room temp

SMILES字符串

FC(F)(F)C(F)(F)C(F)(F)C(=O)OC(=O)C(F)(F)C(F)(F)C(F)(F)F

InChI

1S/C8F14O3/c9-3(10,5(13,14)7(17,18)19)1(23)25-2(24)4(11,12)6(15,16)8(20,21)22

InChI key

UFFSXJKVKBQEHC-UHFFFAOYSA-N

正在寻找类似产品? 访问 产品对比指南

应用

七氟丁酸酐可用作衍生剂,用于测定:
  • 污水污泥样品中的烷基酚聚氧乙烯醚和溴化阻燃剂
  • GC分析甘蔗中的游离氨基酸。

包装

5ML和25ML玻璃瓶装

10 AMP安剖瓶装

象形图

Corrosion

警示用语:

Danger

危险声明

危险分类

Skin Corr. 1B

储存分类代码

8A - Combustible corrosive hazardous materials

WGK

WGK 3

闪点(°F)

Not applicable

闪点(°C)

Not applicable

个人防护装备

Faceshields, Gloves, Goggles, type ABEK (EN14387) respirator filter


从最新的版本中选择一种:

分析证书(COA)

Lot/Batch Number

没有发现合适的版本?

如果您需要特殊版本,可通过批号或批次号查找具体证书。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

An integrated method for the simultaneous determination of alkylphenol ethoxylates and brominated flame retardants in sewage sludge samples by ultrasonic-assisted extraction, solid phase clean-up, and GC-MS analysis
Chokwe T, et al.
Microchemical Journal, Devoted to the Application of Microtechniques in All Branches of Science, 123, 230-236 (2015)
Anne Bohin et al.
Analytical biochemistry, 340(2), 231-244 (2005-04-21)
In previous articles [Anal. Biochem. 284 (2000) 201; J. Lipid Res. 43 (2002) 794], we reported that the GC/MS identification and quantification of nearly all constituents of glycolipids could be obtained on the same sample in a single GC/MS analysis
Ronald Agius et al.
Forensic science international, 196(1-3), 3-9 (2010-01-12)
The analysis of ethyl glucuronide (EtG) in hair is a powerful tool for chronic alcohol abuse control because of the typical wide detection window of the hair matrix and due to the possibility of segmentation, allowing evaluation of alcohol consumption
O Beck et al.
Journal of analytical toxicology, 22(1), 45-49 (1998-03-10)
The use of mushrooms containing the hallucinogenic substance psilocybin for intentional intoxication is relatively common. Occasionally, this results in adverse reactions with typical tachycardia that is not evidently caused by psilocybin. This study demonstrates the presence of phenylethylamine in the
Oliver Lerch et al.
Journal of chromatography. A, 991(1), 77-97 (2003-04-22)
Methods for ultra trace detection of endocrine disruptive chemicals (EDCs) are needed because of their low levels of impact. Twenty-one EDCs were selected, including 17beta-estradiol, 17alpha-ethinylestradiol, 17beta-testosterone and bisphenol A. Derivatisation with eight different fluorine containing compounds was examined. All

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门