跳转至内容
Merck
CN
  • Chronic electrical stimulation with a suprachoroidal retinal prosthesis: a preclinical safety and efficacy study.

Chronic electrical stimulation with a suprachoroidal retinal prosthesis: a preclinical safety and efficacy study.

PloS one (2014-05-24)
David A X Nayagam, Richard A Williams, Penelope J Allen, Mohit N Shivdasani, Chi D Luu, Cesar M Salinas-LaRosa, Sue Finch, Lauren N Ayton, Alexia L Saunders, Michelle McPhedran, Ceara McGowan, Joel Villalobos, James B Fallon, Andrew K Wise, Jonathan Yeoh, Jin Xu, Helen Feng, Rodney Millard, Melanie McWade, Patrick C Thien, Chris E Williams, Robert K Shepherd
摘要

To assess the safety and efficacy of chronic electrical stimulation of the retina with a suprachoroidal visual prosthesis. Seven normally-sighted feline subjects were implanted for 96-143 days with a suprachoroidal electrode array and six were chronically stimulated for 70-105 days at levels that activated the visual cortex. Charge balanced, biphasic, current pulses were delivered to platinum electrodes in a monopolar stimulation mode. Retinal integrity/function and the mechanical stability of the implant were assessed monthly using electroretinography (ERG), optical coherence tomography (OCT) and fundus photography. Electrode impedances were measured weekly and electrically-evoked visual cortex potentials (eEVCPs) were measured monthly to verify that chronic stimuli were suprathreshold. At the end of the chronic stimulation period, thresholds were confirmed with multi-unit recordings from the visual cortex. Randomized, blinded histological assessments were performed by two pathologists to compare the stimulated and non-stimulated retina and adjacent tissue. All subjects tolerated the surgical and stimulation procedure with no evidence of discomfort or unexpected adverse outcomes. After an initial post-operative settling period, electrode arrays were mechanically stable. Mean electrode impedances were stable between 11-15 kΩ during the implantation period. Visually-evoked ERGs & OCT were normal, and mean eEVCP thresholds did not substantially differ over time. In 81 of 84 electrode-adjacent tissue samples examined, there were no discernible histopathological differences between stimulated and unstimulated tissue. In the remaining three tissue samples there were minor focal fibroblastic and acute inflammatory responses. Chronic suprathreshold electrical stimulation of the retina using a suprachoroidal electrode array evoked a minimal tissue response and no adverse clinical or histological findings. Moreover, thresholds and electrode impedance remained stable for stimulation durations of up to 15 weeks. This study has demonstrated the safety and efficacy of suprachoroidal stimulation with charge balanced stimulus currents.

材料
货号
品牌
产品描述

Sigma-Aldrich
抗胶质纤维酸性蛋白(GFAP)抗体, serum, Chemicon®
Sigma-Aldrich
抗谷氨酰胺合成酶抗体,克隆GS-6, clone GS-6, Chemicon®, from mouse
Sigma-Aldrich
单克隆抗 神经丝蛋白 200(磷酸盐和磷酸盐) 小鼠抗, clone N52, ascites fluid
异氟醚, European Pharmacopoeia (EP) Reference Standard