  • Radiologic-pathologic analysis of increased ethanol localization and ablative extent achieved by ethyl cellulose.

Radiologic-pathologic analysis of increased ethanol localization and ablative extent achieved by ethyl cellulose.

Scientific reports (2021-10-21)
Erika Chelales, Robert Morhard, Corrine Nief, Brian Crouch, Jeffrey I Everitt, Alan Alper Sag, Nirmala Ramanujam
摘要

Ethanol provides a rapid, low-cost ablative solution for liver tumors with a small technological footprint but suffers from uncontrolled diffusion in target tissue, limiting treatment precision and accuracy. Incorporating the gel-forming polymer ethyl cellulose to ethanol localizes the distribution. The purpose of this study was to establish a non-invasive methodology based on CT imaging to quantitatively determine the relationship between the delivery parameters of the EC-ethanol formulation, its distribution, and the corresponding necrotic volume. The relationship of radiodensity to ethanol concentration was characterized with water-ethanol surrogates. Ex vivo EC-ethanol ablations were performed to optimize the formulation (n = 6). In vivo ablations were performed to compare the optimal EC-ethanol formulation to pure ethanol (n = 6). Ablations were monitored with CT and ethanol distribution volume was quantified. Livers were removed, sectioned and stained with NADH-diaphorase to determine the ablative extent, and a detailed time-course histological study was performed to assess the wound healing process. CT imaging of ethanol-water surrogates demonstrated the ethanol concentration-radiodensity relationship is approximately linear. A concentration of 12% EC in ethanol created the largest distribution volume, more than eight-fold that of pure ethanol, ex vivo. In vivo, 12% EC-ethanol was superior to pure ethanol, yielding a distribution volume three-fold greater and an ablation zone six-fold greater than pure ethanol. Finally, a time course histological evaluation of the liver post-ablation with 12% EC-ethanol and pure ethanol revealed that while both induce coagulative necrosis and similar tissue responses at 1-4 weeks post-ablation, 12% EC-ethanol yielded a larger ablation zone. The current study demonstrates the suitability of CT imaging to determine distribution volume and concentration of ethanol in tissue. The distribution volume of EC-ethanol is nearly equivalent to the resultant necrotic volume and increases distribution and necrosis compared to pure ethanol.

材料
货号
品牌
产品描述

Sigma-Aldrich
还原型 β-烟酰胺腺嘌呤二核苷酸 二钠盐 水合物, ≥97% (HPLC)
Sigma-Aldrich
氯化四唑氮蓝, ≥90.0% (HPLC)
Sigma-Aldrich
Krebs-Ringer碳酸氢盐缓冲液, With 1800 mg/L glucose, without calcium chloride and sodium bicarbonate, powder, suitable for cell culture