跳转至内容
Merck
CN

A simpler potentiometric method for histamine assessment in blood sera.

Analytical and bioanalytical chemistry (2020-04-03)
A R Pereira, A N Araújo, M C B S M Montenegro, C M P Gomes Amorim
摘要

Histamine intolerance results from a disequilibrium of accumulated histamine and the capacity for histamine degradation. An impaired histamine degradation based on reduced DAO activity and the resulting histamine excess may cause numerous symptoms mimicking an allergic reaction. For that, the determination of histamine in blood or in food products has great importance to identify risk factors. A new histamine-selective electrode is proposed using cucurbit[6]uril (CB[6]), as ionophore, in the analysis of biological samples. The selection of this smart supramolecular organic framework was based on its apparent stability constant of histamine-CB[6] (log β) of 4.33. The optimized electrode based on a polymeric membrane (PVC) combines the histamine-selective ionophore with 2-nitrophenyl octyl ether as solvent mediator and potassium tetrakis(4-chlorophenyl)borate as anionic additive. Furthermore, multi-walled carbon nanotubes particles were included in the membrane composition to partly lower the detection limit of the method, while improving stability and lowering the response drift (± 4 mV). The electrodes showed a rapid response (≃ 13 s) in the pH operational range of 2.7-5.4, with a Nernstian slope of 30.9 ± 1.2 mV/dec, a detection limit of (3.00 ± 0.61) × 10-7 mol/L, and a lower limit of the linear range of (3.00 ± 0.00) × 10-7 mol/L. After miniaturization, the electrode was used as a detector in a sequential-injection lab-on-valve flow setup. The optimized flow conditions were achieved for sample injection volumes of 197 μL propelled towards the cell under detection, at a flow rate of 30 μL/s during 100 s, making the analysis of 30 samples per hour possible. The developed system was used to analyze spiked blood serum samples previously cleaned by using solid-phase extraction. The sample pretreatment of the serum samples using Oasis MCX cartridges showed outstanding efficiency for histamine determination. The recovery values for three different levels of histamine concentration (1 × 10-4 mol/L, 1 × 10-5 mol/L, and 1 × 10-6 mol/L) were (97 ± 6)%, (103 ± 1)%, and (118 ± 9)%, respectively, showing that this method was suitable for biological samples.

材料
货号
品牌
产品描述

Sigma-Aldrich
氯化锂, ACS reagent, ≥99%
Sigma-Aldrich
四氢呋喃, anhydrous, contains 250 ppm BHT as inhibitor, ≥99.9%
Sigma-Aldrich
氯化镁, anhydrous, ≥98%
Sigma-Aldrich
组胺 二盐酸盐, ≥99% (TLC), powder
Sigma-Aldrich
腐胺 二盐酸盐, ≥98% (TLC)
Sigma-Aldrich
尸胺 二盐酸盐, ≥99.0% (AT)
Supelco
聚氯乙烯, Selectophore, high molecular weight
Sigma-Aldrich
氯化钙
Supelco
四(4-氯苯基)硼酸钾, Selectophore, ≥98.0%
Sigma-Aldrich
葫芦脲 水合物, contains acid of crystalization
Supelco
2-硝基苯辛醚, Selectophore, ≥99.0%
Sigma-Aldrich
α-环糊精, purum, ≥98.0% (HPLC)