技术
LC/MS: suitable
solid phase extraction (SPE): suitable
试验参数
sample preparation: SPE (Solid Phase Extraction)
sample/matrix: whole pasteurized milk spiked with chloramphenicol at 15 ng/mL and 38 ng/mL
SPE tube/cartridge: SupelMIP SPE - Chloramphenicol, 25 mg/10mL (LRC) (53210-U)
condition: 1 mL methanol;1 mL DI water
sample addition: 1 mL
washing: 2 x 1 mL MS-grade water, 1 mL 5% acetonitrile in 0.5% acetic acid, 2 x 1 mL MS-grade water, 1 mL 20% acetonitrile in 1% ammonium hydroxide. (dry SPE tubes for 15 min. under gentle vacuum; 3 x 1 mL dichloromethane; dry SPE tubes for 1 min. under gentle vacuum)
elution: elute chloramphenicol with 2 x 1 mL methanol:acetic acid:MS-grade water (89:1:10, v/v/v)
eluate post-treatment: evaporate combined eluate to dryness at 50 °C under nitrogen. reconstitute in 150 mL LC mobile phase prior to LC-MS analysis
column: Ascentis C18, 2.1 mm x 10 cm I.D., 3 μm particles (581301-U)
mobile phase: [A] 100 mM ammonium acetate: [B] MS-grade water: [C] acetonitrile (10:60:30, A:B:C)
flow rate: 0.2 mL/min
column temp.: 35 °C
detector: MS, ESI(-), 320-323 m/z range
injection: 5 μL
适用性
application for LC-MS
application for SPE
应用
food and beverages
法律信息
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门