跳转至内容
Merck
CN

53304-U

Supelco

Ascentis® Express Peptide 160 Å ES-C18 (2.7 μm) HPLC Columns

L × I.D. 7.5 cm × 2.1 mm, HPLC Column

别名:

TM=["Ascentis"] Peptide Chromatography

登录查看公司和协议定价


About This Item

UNSPSC代码:
41115700
eCl@ss:
32110501
NACRES:
SB.52

product name

Ascentis® Express Peptide ES-C18, 2.7μm HPLC 色谱柱, 2.7 μm particle size, L × I.D. 7.5 cm × 2.1 mm

物料

stainless steel column

质量水平

Agency

suitable for USP L1

产品线

Ascentis®

特点

endcapped: no

制造商/商品名称

Ascentis®

包装

1 ea of

参数

≤100 °C temp. range
600 bar max. pressure (9000 psi)

技术

HPLC: suitable
LC/MS: suitable
UHPLC-MS: suitable
UHPLC: suitable

长度 × 内径

7.5 cm × 2.1 mm

表面积

90 m2/g

杂质

<5 ppm metals

基质

Fused-Core particle platform
superficially porous particle

基质活性基团

C18 (octadecyl) phase

粒径

2.7 μm

孔径

160 Å

operating pH range

1-9

分离技术

reversed phase

正在寻找类似产品? 访问 产品对比指南

相关类别

一般描述

Ascentis Express Peptide ES-C18 色谱柱是专为分离肽和小分子蛋白等高分子量化合物而设计的。这些色谱柱含有先进的熔融核心颗粒,这些颗粒具有较大的孔隙(标准 Ascentis Express 中的 160Å与 90Å),与立体保护的 C18 配体结合,以提供极低 pH 值 (<1) 和高温(高达 100ºC)下的额外稳定性 (ES)。这大大扩展了 Ascentis Express 色谱柱的应用范围。

法律信息

Ascentis is a registered trademark of Merck KGaA, Darmstadt, Germany

WGK

WGK 3

闪点(°F)

Not applicable

闪点(°C)

Not applicable


Choose from one of the most recent versions:

分析证书(COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

  1. Which document(s) contains shelf-life or expiration date information for a given product?

    If available for a given product, the recommended re-test date or the expiration date can be found on the Certificate of Analysis.

  2. How do I get lot-specific information or a Certificate of Analysis?

    The lot specific COA document can be found by entering the lot number above under the "Documents" section.

  3. What is special about Ascentis Express?

    Ascentis Express columns provide a breakthrough in HPLC performance. Based on Fused-Core particle technology, Ascentis Express provides the benefits of sub-2 μm particles but at much lower backpressure.  These benefits include the capability of providing fast HPLC and higher resolution chromatography.  The Fused-Core particle consists of a 1.7 μm solid core and a 0.5 μm porous shell.  A major benefit of the Fused-Core particle is the small diffusion path (0.5 μm) compared to conventional fully porous particles. The shorter diffusion path reduces axial dispersion of solutes and minimizes peak broadening.

  4. How do I find price and availability?

    There are several ways to find pricing and availability for our products. Once you log onto our website, you will find the price and availability displayed on the product detail page. You can contact any of our Customer Sales and Service offices to receive a quote.  USA customers:  1-800-325-3010 or view local office numbers.

  5. What is the Department of Transportation shipping information for this product?

    Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product. 

  6. How can I measure my instrument bandwidth (IBW) and determine what columns can be used with minimal efficiency loss created by too much internal instrument volume?

    The Guide to Dispersion Measurement has simple instructions on how to measure IBW and can be found at sigma-aldrich.com/express.

  7. What is special about product 53304-U Ascentis® Express Peptide ES C18 HPLC Column?

    Product 53304-U Ascentis® Express Peptide ES C18 HPLC Column provides a breakthrough in HPLC performance. Based on Fused-Core particle technology, Ascentis® Express columns provide the benefits of sub-2 μm particles but at much lower backpressure.  These benefits include the capability of providing fast HPLC and higher resolution chromatography.  The Fused-Core particle consists of a 1.7 μm solid core and a 0.5 μm porous shell.  A major benefit of the Fused-Core particle is the small diffusion path (0.5 μm) compared to conventional fully porous particles. The shorter diffusion path reduces axial dispersion of solutes and minimizes peak broadening.

  8. Are guard columns available for product 53304-U Ascentis® Express Peptide ES C18 HPLC Column?

    Yes, we have guard columns available for product 53304-U Ascentis® Express Peptide ES C18 HPLC Column.  Product 53500-U is the Ascentis® Express Guard Holder and Product 53536-U Ascentis® Express Peptide ES C18 Guard Cartridge is a package of three guard cartridges, 2.7 μm particle size, L 5mm × I.D. 2.1 mm .

  9. Can I use product 53304-U Ascentis® Express Peptide ES C18 HPLC Column on any type of HPLC system?

    Product 53304-U Ascentis® Express Peptide ES C18 HPLC Column HPLC columns is capable of use on standard HPLC systems as well as UHPLC systems.  This column is packed in high pressure hardware capable of withstanding the pressures used in UHPLC systems.

  10. Can I use product 53304-U Ascentis® Express Peptide ES C18 HPLC Column on a UHPLC system?

    Yes.  product 53304-U Ascentis® Express Peptide ES C18 HPLC columns are packed in a way making them suitable for these ultra high pressure instruments.  In fact, product 53304-U Ascentis® Express Peptide ES C18 HPLC Column outperforms sub-2 μm micron columns on many applications since product 53304-U Ascentis® Express Peptide ES C18 HPLC Column provides the benefits of sub-2 μm particles but at much lower back pressure.  These benefits include the capability of providing fast HPLC and higher resolution chromatography.  The Fused-Core particle consists of a 1.7 μm solid core and a 0.5 μm porous shell.  A major benefit of the Fused-Core particle is the small diffusion path (0.5 μm) compared to conventional fully porous particles. The shorter diffusion path reduces axial dispersion of solutes and minimizes peak broadening.

  11. What flow rate should I use with product 53304-U Ascentis® Express Peptide ES C18 HPLC columns?

    Based on the minimum in the van Deemter curves, higher flows than 5um particle columns are required in order to maximize product 53304-U Ascentis® Express Peptide ES C18 HPLC column efficiency. The suggested starting point for flow rate for Ascentis® Express columns: 1.6 mL/min for 4.6 mm ID;  0.8 mL/min for 3.0 mm ID; and 0.4mL/min for 2.1 mm ID.

  12. Do I need special fittings and tubing to connect product 53304-U Ascentis® Express Peptide ES C18 HPLC ColumnExpress columns?

    While operating pressures may not exceed the 400 bar (6,000 psi) capability of your traditional instruments, sustained pressures of about 200 bar (3,000 psi) will exceed the recommended pressure for conventional PEEK tubing and fittings at the column inlet. We recommend changing to stainless steel fittings in all high pressure locations and have designed special High Performance HPLC Fittings/Interconnects that will stay tight at pressures of 1,000 bar (15,000 psi) or greater, even when elevated column temperatures are employed.

  13. Is there anything special I need to do to my HPLC system to use product 53304-U Ascentis® Express Peptide ES C18 HPLC Column?

    Nothing special is required to use product 53304-U Ascentis® Express Peptide ES C18 HPLC Column. To obtain the full benefits of Ascentis® Express Column, one should minimize dispersion or instrument bandwidth in the HPLC system (tubing, detector flow cell) as well as confirm the detector response system is set at a fast level. For more information, request Guidelines for Optimizing Performance with Ascentis® Express HPLC Columns (T407102).

  14. Can product 53304-U Ascentis® Express Peptide ES C18 HPLC column be used for LC-MS?

    Yes, Express Fused-Core particles were designed with LC-MS in mind. Even extremely short column lengths exhibit sufficient plate counts to show high resolving power. The flat van Deemter plots permit resolution to be maintained at very high flow rates to maximize sample throughput. All Ascentis stationary phases have been evaluated for MS compatibility during their development, and the Express phases are no exception. You can expect extremely low column bleed and background while maintaining longest possible column lifetime. A bonus of product 53304-U Ascentis® Express Peptide ES C18 HPLC Column for high throughput UHPLC and LC-MS is that they are extremely rugged and highly resistant to plugging, a very common failure mode for competitor columns.

  15. What is the pressure rating for product 53304-U Ascentis® Express Peptide ES C18 HPLC Column?

    This product 53304-U Ascentis® Express Peptide ES C18 HPLC Column is stable to operating pressures up to 600 bar (9000 psi)

  16. What is the carbon load for product 53304-U Ascentis® Express Peptide ES C18 HPLC Column?

    Carbon load which is commonly referred to as %Carbon is misleading and not meaningful for Ascentis Express. Since Fused-Core particle is unique in the sense that it has a solid core and porous shell, the %Carbon number can not be compared to traditional porous particles.  The carbon coverage for product 53304-U Ascentis® Express Peptide ES C18 HPLC column is 2 micromoles/meter-squared.

  17. My question is not addressed here, how can I contact Technical Service for assistance?

    Ask a Scientist here.

E Lesellier
Journal of chromatography. A, 1266, 34-42 (2012-11-03)
The recent introduction of new stationary phases for liquid chromatography based on superficially porous particles, called core-shell or fused-core, dramatically improved the separation performances through very high efficiency, due mainly to reduced eddy diffusion. However, few studies have evaluated the
Meiyun Shi et al.
Journal of separation science, 38(8), 1351-1357 (2015-01-30)
The pentapeptide thymopentin (Arg-Lys-Asp-Val-Tyr, RKDVY) corresponds to amino acids 32-36 of the 49 amino acid immunomodulatory polypeptide, thymopoietin, whose biological activity is partially reproduced. Thymopentin is widely used in the clinic and represents a promising target for drug design but
C Gröer et al.
Journal of pharmaceutical and biomedical analysis, 100, 393-401 (2014-09-15)
Cytochrome P450 (CYP) enzymes and UDP-glucuronosyltransferases (UGT) are major determinants in the pharmacokinetics of most drugs on the market. To investigate their impact on intestinal and hepatic drug metabolism, we developed and validated quantification methods for nine CYP (CYP1A2, CYP2B6

商品

Choose Ascentis® Express Peptide ES-C18 U/HPLC Columns based on Fused-Core® technology for fast and efficient separation of high-molecular weight compounds, such as peptides and small proteins. With a 2.7 µm particle size and rigorous testing, these columns offer reliable results and high efficiency.

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门