产品名称
SGE 注射器阀, Luer Lock with Luer Tip, volume 50-20000 μL, for use with any Luer lock syringe
material
stainless steel body
description
push button
packaging
pkg of 1 ea
manufacturer/tradename
SGE 031915
volume
50-20000 μL
compatibility
for use with any Luer lock syringe
正在寻找类似产品? 访问 产品对比指南
General description
带有 Kel-F 旋转锁定公接头的按钮阀
Syringe valves are ideal for sample storage and transportation or to pressurize samples prior to injection. SGE offers several types of manually-operated syringe valves: push-pull for smaller volumes (2.5 μL-2.5 mL) and push-button valves (50 μL-2 L). SGE Luer Tip, Luer Lock and removable needle syringes can be fitted with valves. The valve allows fluid to be stored in the syringe without contamination.
Cat. No. 509337 is a push-pull valve with removable 0.63 mm O.D. × 5 cm cone tip needle. This valve will fit removable needle syringes, 25μL-2.5mL.
Cat. No. 509345 is a push-pull with Kel-F male Luer lock termination to fit removable needle syringes, 25μL-2.5mL
Cat. No. 509353 is a push-button with Kel-F male Luer lock termination. This fits 5 mL to 2 liter syringes with removable Luer Lock or removable needle.
Cat. No. 509361 is a Luer Lock valve for any Luer Lock and Luer Tip syringe (50μl to 2 liter).
Cat. No. 509337 is a push-pull valve with removable 0.63 mm O.D. × 5 cm cone tip needle. This valve will fit removable needle syringes, 25μL-2.5mL.
Cat. No. 509345 is a push-pull with Kel-F male Luer lock termination to fit removable needle syringes, 25μL-2.5mL
Cat. No. 509353 is a push-button with Kel-F male Luer lock termination. This fits 5 mL to 2 liter syringes with removable Luer Lock or removable needle.
Cat. No. 509361 is a Luer Lock valve for any Luer Lock and Luer Tip syringe (50μl to 2 liter).
Application
SGE syringe valves may be used with gas tight syringes, for introduction of samples to the gas sampling and injection system (GASIS) inlet, in an experimental study conducted for the analyses of compound-specific δD and δ13C gas mixtures using gas chromatography-oxidation/reduction-isotope ratio mass spectrometry.