推荐产品
等级
analytical standard
质量水平
蒸汽密度
5.04 (vs air)
蒸汽压
12.85 psi ( 20 °C)
39.17 psi ( 55 °C)
CofA
current certificate can be downloaded
包装
ampule of 5000 mg
技术
HPLC: suitable
gas chromatography (GC): suitable
折射率
n20/D 1.3821 (lit.)
沸点
23.7 °C (lit.)
mp
−111-−110 °C (lit.)
密度
1.494 g/mL at 25 °C (lit.)
应用
cleaning products
cosmetics
environmental
food and beverages
personal care
包装形式
neat
储存温度
2-8°C
SMILES字符串
FC(Cl)(Cl)Cl
InChI
1S/CCl3F/c2-1(3,4)5
InChI key
CYRMSUTZVYGINF-UHFFFAOYSA-N
正在寻找类似产品? 访问 产品对比指南
应用
Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.
法律信息
Freon is a registered trademark of E. I. du Pont de Nemours and Company
Konrad Stemmler et al.
Environmental science & technology, 41(4), 1145-1151 (2007-06-28)
HFC-365mfc (1,1,1,3,3-pentafluorobutane) is an industrial chemical used for polyurethane foam blowing. From early 2003, HFC-365mfc has been commercially produced as a substitute for HCFC-141b, whose use in Europe has been banned since January 2004. We describe the first detection of
A Vinegar
Toxicological sciences : an official journal of the Society of Toxicology, 60(1), 20-27 (2001-02-27)
Human exposure guidelines for halogenated hydrocarbons (halons) and halon replacement chemicals have been established using dose-response data obtained from canine cardiac sensitization studies. In order to provide a tool for decision makers and regulators tasked with setting guidelines for egress
Kai Sheng Diao et al.
Bulletin of environmental contamination and toxicology, 84(2), 170-174 (2009-11-28)
Ab initio calculations have been performed on complexes of CFCl3 with SO2. Ten complexes were found stable, the interaction energies that reflect their stability were corrected by the basis set superposition error and the correction of zero-point energy. The natures
W R Elliot et al.
Journal of clinical monitoring, 7(2), 175-180 (1991-04-01)
Spurious readings from a mass spectrometer have been reported following the administration of aerosol bronchodilators. We quantified the response of various respiratory gas analyzers to the aerosol propellant of albuterol inhalant (Proventil). The mass spectrometer systems tested, two Advantage systems
D N Sonier et al.
Applied and environmental microbiology, 60(12), 4567-4572 (1994-12-01)
Groundwater samples were obtained from a deep aquifer contaminated with halogenated aliphatic compounds. One-milliliter samples contained 9.2 x 10(5) total bacteria (by acridine orange microscopic counts) and 2.5 x 10(3) sulfate-reducing bacteria (by most probable number analysis). Samples were incubated
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门