EPA TO-15/17校准混标

62 components, 1 ppm in nitrogen, cylinder of 110 L (pi-marked cylinder), analytical standard

登录 查看组织和合同定价。

选择尺寸


关于此项目

UNSPSC Code:
77101502
EC Number:
231-783-9
NACRES:
NA.24
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助

grade

analytical standard

agency

EPA TO-15,TO-17

shelf life

12 mo.

feature

standard type calibration

packaging

cylinder of 110 L (pi-marked cylinder)

manufacturer/tradename

Air Liquide America Specialty Gases LLC TAZ70002-110

concentration

1 ppm in nitrogen

technique(s)

HPLC: suitable, gas chromatography (GC): suitable

application(s)

environmental

format

multi-component solution

General description

EPA TO-15/17 Calibration mix is a quantitative formulation for use as a chromatographic calibration standard for the determination of volatile organic compounds (VOCs) by gas chromatography-mass spectrometry (GC-MS). It may also be used as a chemical reference standard for the qualitative calibration of air monitoring and industrial hygiene equipment.
These standards are available in both liquid solutions and gaseous blends, to accommodate calibration of today′s variety of air monitoring and analysis devices and applications. Each standard includes a Certificate of Analysis summarizing the testing data. Each standard solution is provided in a flame-sealed amber ampoule. Each gaseous standard is provided in a transportable cylinder for ease of use in either the laboratory or the field.

Application

EPA TO-15/17 Calibration mix (62 components, 1 ppm in nitrogen) may be used as an analytical standard to quantify volatile organic compounds (VOCs) in food waste emissions as well as ambient and atmospheric air samples by GC-MS.
Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.

Features and Benefits

Cylinder specifications:
Pressure:1800 psig
Outlet fitting:CGA 180
Weight:2.2lbs. (1kg)
Dimensions:3.25in D X 11.625in H (82.6mm X 295.3mm)

U.S. D.O.T. specs: 3AL2216
The Scotty TO-15/17 gas calibration mix is supplied in an Extra-Life transportable aluminum cylinder which features the exclusive ACULIFE cylinder treatment process for guaranteed mixture stability.

Blend tolerance and analytical accuracy = +/- 10% for all components except benzyl chloride, carbon disulfide, ethanol, 2-propanol which are +/- 25%.

Legal Information

ACULIFE is a trademark of Air Liquide

分析物

说明

    Acetone
    Benzene
    Benzyl chloride
    Bromoform
    Bromomethane
    Bromodichloromethane
    1,3-Butadiene
    2-Butanone
    Carbon disulfide
    Carbon tetrachloride
    Chlorobenzene
    Chloroethane
    Chloroform
    Cyclohexane
    Chloromethane
    Dibromochloromethane
    1,2-Dichlorobenzene
    1,3-Dichlorobenzene
    1,4-Dichlorobenzene
    1,1-Dichloroethane
    1,2-Dichloroethane
    1,1-Dichloroethylene
    cis-1,2-Dichloroethylene
    trans-1,2-Dichloroethylene
    1,2-Dichloropropane
    cis-1,3-Dichloropropene
    trans-1,3-Dichloropropene
    1,4-Dioxane
    Ethanol
    Ethyl acetate
    Ethylbenzene
    1,2-Dibromoethane
    4-Ethyltoluene
    Trichlorofluoromethane
    Dichlorodifluoromethane
    1,1,2-Trichloro-1,2,2-trifluoroethane
    1,2-Dichlorotetrafluoroethane
    Heptane
    Hexachloro-1,3-butadiene
    Hexane
    2-Hexanone
    4-Methyl-2-pentanone
    Dichloromethane
    tert-Butyl methyl ether
    2-Propanol
    Propylene
    Styrene
    1,1,2,2-Tetrachloroethane
    Tetrachloroethylene
    Tetrahydrofuran
    Toluene
    1,1,1-Trichloroethane
    1,1,2-Trichloroethane
    Trichloroethylene
    1,2,4-Trichlorobenzene
    1,2,4-Trimethylbenzene
    Mesitylene
    Vinyl acetate
    Vinyl chloride
    m-Xylene
    o-Xylene
    p-Xylene
    查看所有结果 (62)

pictograms

Gas cylinder

signalword

Warning

hcodes

法规信息

监管及禁止进口产品
此项目有

历史批次信息供参考:

分析证书(COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our 文件 section.

如需帮助,请联系 客户支持

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Reduction of ammonia and volatile organic compounds from food waste-composting facilities using a novel anti-clogging biofilter system
Ryu HW, et al.
Bioresource Technology, 102(7), 4654-4660 (2011)
Spatiotemporal Variations and Health Implications of Hazardous Air Pollutants in Ulsan, a Multi-Industrial City in Korea
Baek KM, et al.
Chemosphere, 11(5), 547-547 (2020)
Occurrence and concentrations of toxic VOCs in the ambient air of Gumi, an electronics-industrial city in Korea
Baek SO, et al.
Sensors, 15(8), 19102-19123 (2015)
Characterization and health impact assessment of hazardous air pollutants in residential areas near a large iron-steel industrial complex in Korea
Baek KM, et al.
Atmospheric Pollution Research, 11(10), 1754-1766 (2020)

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系客户支持