等级
analytical standard
Agency
EPA TO-15,TO-17
保质期
12 mo.
特点
standard type calibration
包装
cylinder of 110 L (pi-marked cylinder)
制造商/商品名称
Air Liquide America Specialty Gases LLC TAZ70002-110
浓度
1 ppm in nitrogen
技术
HPLC: suitable
gas chromatography (GC): suitable
应用
environmental
格式
multi-component solution
一般描述
EPA TO-15/17 Calibration mix is a quantitative formulation for use as a chromatographic calibration standard for the determination of volatile organic compounds (VOCs) by gas chromatography-mass spectrometry (GC-MS). It may also be used as a chemical reference standard for the qualitative calibration of air monitoring and industrial hygiene equipment.
These standards are available in both liquid solutions and gaseous blends, to accommodate calibration of today′s variety of air monitoring and analysis devices and applications. Each standard includes a Certificate of Analysis summarizing the testing data. Each standard solution is provided in a flame-sealed amber ampoule. Each gaseous standard is provided in a transportable cylinder for ease of use in either the laboratory or the field.
These standards are available in both liquid solutions and gaseous blends, to accommodate calibration of today′s variety of air monitoring and analysis devices and applications. Each standard includes a Certificate of Analysis summarizing the testing data. Each standard solution is provided in a flame-sealed amber ampoule. Each gaseous standard is provided in a transportable cylinder for ease of use in either the laboratory or the field.
应用
EPA TO-15/17 Calibration mix (62 components, 1 ppm in nitrogen) may be used as an analytical standard to quantify volatile organic compounds (VOCs) in food waste emissions as well as ambient and atmospheric air samples by GC-MS.
Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.
特点和优势
The Scotty TO-15/17 gas calibration mix is supplied in an Extra-Life transportable aluminum cylinder which features the exclusive ACULIFE™ cylinder treatment process for guaranteed mixture stability.
Blend tolerance and analytical accuracy = +/- 10% for all components except benzyl chloride, carbon disulfide, ethanol, 2-propanol which are +/- 25%.
Blend tolerance and analytical accuracy = +/- 10% for all components except benzyl chloride, carbon disulfide, ethanol, 2-propanol which are +/- 25%.
产品规格
Cylinder specifications:
Pressure:1800 psig
Outlet fitting:CGA 180
Weight:2.2lbs. (1kg)
Dimensions:3.25in D X 11.625in H (82.6mm X 295.3mm)
U.S. D.O.T. specs: 3AL2216
Pressure:1800 psig
Outlet fitting:CGA 180
Weight:2.2lbs. (1kg)
Dimensions:3.25in D X 11.625in H (82.6mm X 295.3mm)
U.S. D.O.T. specs: 3AL2216
法律信息
ACULIFE is a trademark of Air Liquide
分析物
说明
Acetone
Benzene
Benzyl chloride
Bromoform
Bromomethane
Bromodichloromethane
1,3-Butadiene
2-Butanone
Carbon disulfide
Carbon tetrachloride
Chlorobenzene
Chloroethane
Chloroform
Cyclohexane
Chloromethane
Dibromochloromethane
1,2-Dichlorobenzene
1,3-Dichlorobenzene
1,4-Dichlorobenzene
1,1-Dichloroethane
1,2-Dichloroethane
1,1-Dichloroethylene
cis-1,2-Dichloroethylene
trans-1,2-Dichloroethylene
1,2-Dichloropropane
cis-1,3-Dichloropropene
trans-1,3-Dichloropropene
1,4-Dioxane
Ethanol
Ethyl acetate
Ethylbenzene
1,2-Dibromoethane
4-Ethyltoluene
Trichlorofluoromethane
Dichlorodifluoromethane
1,1,2-Trichloro-1,2,2-trifluoroethane
1,2-Dichlorotetrafluoroethane
Heptane
Hexachloro-1,3-butadiene
Hexane
2-Hexanone
4-Methyl-2-pentanone
Dichloromethane
tert-Butyl methyl ether
2-Propanol
Propylene
Styrene
1,1,2,2-Tetrachloroethane
Tetrachloroethylene
Tetrahydrofuran
Toluene
1,1,1-Trichloroethane
1,1,2-Trichloroethane
Trichloroethylene
1,2,4-Trichlorobenzene
1,2,4-Trimethylbenzene
Mesitylene
Vinyl acetate
Vinyl chloride
m-Xylene
o-Xylene
p-Xylene
查看所有结果 (62)
Spatiotemporal Variations and Health Implications of Hazardous Air Pollutants in Ulsan, a Multi-Industrial City in Korea
Chemosphere, 11(5), 547-547 (2020)
Reduction of ammonia and volatile organic compounds from food waste-composting facilities using a novel anti-clogging biofilter system
Bioresource Technology, 102(7), 4654-4660 (2011)
Characterization and health impact assessment of hazardous air pollutants in residential areas near a large iron-steel industrial complex in Korea
Atmospheric Pollution Research, 11(10), 1754-1766 (2020)
Occurrence and concentrations of toxic VOCs in the ambient air of Gumi, an electronics-industrial city in Korea
Sensors, 15(8), 19102-19123 (2015)
Chromatograms
suitable for GC我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门