Sigma-Aldrich

人类 CD40L ELISA 试剂盒

for serum, plasma, cell culture supernatant and urine

登录查看公司和协议定价


About This Item

UNSPSC代码:
41116158
NACRES:
NA.32

种属反应性

human

包装

kit of 96 wells (12 strips x 8 wells)

技术

ELISA: suitable
capture ELISA: suitable

输入

sample type plasma
sample type cell culture supernatant(s)
sample type serum
sample type urine

assay range

inter-assay cv: <12%
intra-assay cv: <10%
sensitivity: 6 pg/mL
standard curve range: 8.23-6000 pg/mL

检测方法

colorimetric

运输

wet ice

储存温度

−20°C

基因信息

human ... CD40LG(959)

一般描述

The Human CD40L ELISA (Enzyme-Linked Immunosorbent Assay) kit is an in vitro enzyme-linked immunosorbent assay for the quantitative measurement of human CD40L in serum, plasma (EDTA or heparin), cell culture supernatants and urine.

免疫原

Recombinant Human CD40 Ligand

应用

请参考Protocol了解详情。

其他说明

A sample Certificate of Analysis is available for this product.
Please type the word sample in the text box provided for lot number.

试剂盒组分也可单独购买

产品编号
说明
化学品安全说明书

  • RABELADAELISA 1X Assay/Sample Diluent Buffer A (Item D1)化学品安全说明书

  • RABELADBELISA 5X Assay/Sample Diluent Buffer B (Item E1)化学品安全说明书

  • RABSTOP3ELISA Stop Solution (Item I)化学品安全说明书

  • RABTMB3ELISA Colorimetric TMB Reagent (HRP Substrate, Item H)化学品安全说明书

  • RABWASH420X Wash Buffer (Item B)化学品安全说明书

象形图

Corrosion

警示用语:

Warning

危险声明

预防措施声明

危险分类

Met. Corr. 1

储存分类代码

8A - Combustible corrosive hazardous materials

法规信息

新产品

分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Leonardo Lorente et al.
Thrombosis research, 134(4), 832-836 (2014-08-16)
Serum soluble CD40 Ligand (sCD40L) levels, which exhibit prothrombotic and proinflammatory properties, have not been studied in patients with traumatic brain injury (TBI). Thus, the objective of this study was to determine whether serum sCD40L levels are associated with severity
Girish Viswanathan et al.
The Journal of clinical endocrinology and metabolism, 99(6), E1050-E1054 (2014-03-19)
Higher serum TSH levels, both within the reference range and in those with subclinical hypothyroidism (SCH), have been associated with increased risk of atherosclerosis and cardiovascular (CV) events in a number of cross-sectional and longitudinal studies. Our objective was to
Adem Aydın et al.
Journal of orthopaedic research : official publication of the Orthopaedic Research Society, 32(1), 151-158 (2013-10-12)
In this study, analysis and comprehensive comparison of neurogenic differentiation capacity of human bursal tissue-derived-stem cells (hBT-SCs) was aimed with human bone marrow derived mesenchymal stem cells (hBM-MSCs). hBT-SCs was isolated from subacromial bursa tissue (n = 3) by collagen

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门