跳转至内容
Merck
CN

MSQC7

Sigma-Aldrich

SILuMAB 稳定同位素标记的通用单克隆抗体标准品 人

recombinant, expressed in CHO cells

别名:

SILuMAB Stable-Isotope Labeled Universal Monoclonal Antibody Standard human, IgG4 kappa, Isotopically labeled mAb LC/MS Standard, Mass Spectrometry Monoclonal Antibody Standard

登录查看公司和协议定价


About This Item

UNSPSC代码:
12352200
NACRES:
NA.12

重组

expressed in CHO cells

质量水平

抗体产品类型

primary antibodies

检测方案

≥90% (SDS-PAGE)

包装

vial of 100 μg (± 10% Lot-specific vial content given on certificate of analysis)

运输

wet ice

储存温度

−20°C

正在寻找类似产品? 访问 产品对比指南

相关类别

应用

Multiplex Universal Peptide Quant Approach Using Microflow LC/MS/MS for Non-human Preclinical PK Study of Therapeutic Monoclonal Antibodies ( Webinar )

Applying Best-in-Class HPLC Column Technologies to the Analysis of Proteins and Biotherapeutics Using SILuMab ( Webinar )

特点和优势

Universal Peptide Sequence Location
YGPPCPPCPAPEFLGGPSVFLFPPKPK Heavy Chain (IgG4 Stabilized)
VVSVLTVLHQDWLNGK Heavy Chain (IgG1, IgG3, IgG4)
GFYPSDIAVEWESNGQPENNYK Heavy Chain (IgG1, IgG4)
TTPPVLDSDGSFFLYSR Heavy Chain (IgG4)
SGTASVVCLLNNFYPR Light Chain (kappa)
VDNALQSGNSQESVTEQDSK Light Chain (kappa)
DSTYSLSSTLTLSK Light Chain (kappa)

Underlined is a Serine-Proline substitution in the hinge region that is present in many human IgG4-based therapeutic monoclonal antibodies

SILuMab has been validated as an internal standard for quantitation of relevant biotherapeutics in a complex biological matrix by MRM-based LC-MS/MS.
  • SILuMab yielded reproducible, linear curves from 0.1 μg/mL to 1000 μg/mL without enrichment or depletion.
  • Good agreement was observed between multiple peptides derived from the same target.
  • Label incorporation was determined to be >98% by mass spectrometry.
  • Sequence coverage was confirmed by peptide mapping.

外形

Supplied as a lyophilized powder containing phosphate buffered saline

制备说明

Produced utilizing enriched media containing stable isotope labeled amino acids are 13C6, 15N4-labeled arginine and 13C6, 15N2-labeled lysine
SILuMab design is optimized to be used as an internal standard for quantitation of monoclonal antibodies as well as Fc-fusion therapeutics. Because of overlap with the common sequences in the Fc region with candidate antibodies, SILuMab provides univer­sal utility, thus eliminating the need for production of candidate-specific internal standards.

重悬

SILuMab recovery is maximized when 0.1% formic acid is used for reconstitution of the lyophilized product. Reconstitution with other solvents may reduce recovery. Do not freeze after reconstitution.
Procedure
  • Briefly centrifuge the vial at ~10,000 x g to collect the product at the bottom of the vial.
  • Add 500 μL of purified water containing 0.1% formic acid to the vial.
  • Mix the contents by gently inverting the vial a minimum of 5 times.
  • Allow the vial to stand at room temperature for a minimum of 15 minutes and repeat mixing by inversion.

分析说明

SILuMAb K4 Heavy Chain

EVQLVESGGGLVQPGGSLRLSCVASGFTLNNYDMHWVRQGIGKGLEWVSKIGTAGDRYYAGSVKGRFTISRENAKDSLYLQMNSLRVGDAAVYYCARGAGRWAPLGAFDIWGQGTMVTVSSASTKGPSVFPLAPCSRSTSESTAALGCLVKDYFPEPVTVSWNSGALTSGVHTFPAVLQSSGLYSLSSVVTVPSSSLGTKTYTCNVDHKPSNTKVDKRVESKYGPPCPPCPAPEFLGGPSVFLFPPKPKDTLMISRTPEVTCVVVDVSQEDPEVQFNWYVDGVEVHNAKTKPREEQFNSTYRVVSVLTVLHQDWLNGKEYKCKVSNKGLPSSIEKTISKAKGQPREPQVYTLPPSQEEMTKNQVSLTCLVKGFYPSDIAVEWESNGQPENNYKTTPPVLDSDGSFFLYSRLTVDKSRWQEGNVFSCSVMHEALHNHYTQKSLSLSLG

SILuMAb K4 Light Chain

QSALTQPRSVSGSPGQSVTISCTGTSSDIGGYNFVSWYQQHPGKAPKLMIYDATKRPSGVPDRFSGSKSGNTASLTISGLQAEDEADYYCCSYAGDYTPGVVFGGGTKLTVLTVAAPSVFIFPPSDEQLKSGTASVVCLLNNFYPREAKVQWKVDNALQSGNSQESVTEQDSKDSTYSLSSTLTLSKADYEKHKVYACEVTHQGLSSPVTKSFNRGEC

Target overlap areas are underlined

Package size based on protein content determined by A280 using an extinction coefficient (E0.1%) of 1.4
Quantitative
MRM settings provided (xls)

法律信息

This product is licensed under U.S. Patent No. 7,396,688 and foreign counterparts from E. I. du Pont de Nemours and Company. The purchase of this product conveys to the buyer the nontransferable right to use the purchased amount of the product for research and development only, including services for a third party for consideration. The buyer cannot sell or otherwise transfer this product, its components or materials made using this product or its components to a third party. Information about licenses for excluded uses is available from: E. I. du Pont de Nemours and Company; Attn: Associate Director, Commercial Development; DuPont Experimental Station E268; 200 Powdermill Rd.; Wilmington, DE 19803; 1-877-881-9787 (voice), 1-302-695-1437 (fax), licensing@dupont.
SILu is a trademark of Sigma-Aldrich Co. LLC

Not finding the right product?  

Try our 产品选型工具.

WGK

WGK 1

闪点(°F)

Not applicable

闪点(°C)

Not applicable

法规信息

常规特殊物品

分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Carlo O Martins et al.
The Journal of molecular diagnostics : JMD, 22(7), 901-911 (2020-04-18)
Multiple myeloma is a systemic malignancy of monoclonal plasma cells that accounts for 10% of hematologic cancers. With development of highly effective therapies for multiple myeloma, minimal residual disease (MRD) assessment has emerged as an important end point for management

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门