跳转至内容
Merck
CN
所有图片(2)

文件

安全信息

GE11-0034-94

HiTrap® MabSelect SuRe

Cytiva 11-0034-94, pack of 1 × 5 mL

登录查看公司和协议定价

UNSPSC代码:
23151816
NACRES:
NA.56

ligand

alkali-stabilized protein A-derived (E. coli)

包装

pack of 1 × 5 mL

制造商/商品名称

Cytiva 11-0034-94

储存条件

(20% Ehtanol)
(20% Ethanol)

参数

<20 mL/min flow rate
42 psi

柱床尺寸

16 mm × 25 mm

柱床体积

5 mL

色谱柱内径

16 mm

基质

highly cross-linked agarose

平均零件尺寸

85 μm (d₅₀v is the median particle size of the cumulative volume distribution)

cleaning

2-13.7

working range

3-12(pH below 3 is sometimes required to elute strongly bound IgG species. However, protein ligands may hydrolyze at very low pH.)

容量

≥30 mg binding capacity (humanlgG/ml at 2.4 min residence time)(Determined at 10% breakthrough by frontal analysis at a mobile phase velocity of 500 cm/h in a column with a bed height of 20 cm.)

适用性

suitable for bioprocess medium

储存温度

2-8°C

正在寻找类似产品? 访问 产品对比指南

相关类别

一般描述

HiTrap® MabSelect SuRe columns are prepacked with MabSelect SuRe, a BioProcess medium for purification of monoclonal antibodies from large sample volumes. The novel alkali-tolerant recombinant Protein A ligand allow cleaning-in-place (CIP).

HiTrap® MabSelect columns are prepacked with MabSelect a bioprocess medium for capuring of Mabs from large sample volumes.

特点和优势

  • Withstands rigorous CIP and sanitization procedures with 0.1 to 0.5 M NaOH.
  • Novel ligand design gives enhanced protease resistance resulting in lower ligand leakage.
  • Oriented coupling of recombinant Protein A to the matrix via an engineered C-terminal cysteine enhances IgG binding capacity.
  • Fewer regulatory concerns due to the total absence of mammalian culture in the ligand production and purification.
  • Prepacked HiTrap® columns for process development, screening of purification conditions, and small-scale purification of Mabs.

分析说明

To view the Certificate of Analysis for this product, please visit www.cytiva.com.

其他说明

1)The pressure over the packed bed varies depending on a range of parameters such as the characteristics of the chromatography medium and the column tubing used.
The pressure over the packed bed varies depending on a range of parameters such as the characteristics of the chromatography medium and the column tubing used.

法律信息

Free MabSelect SuRe Ligand
"MabSelect SuRe Ligand Restricted License" and "Cys-rProtein A Ligand Restricted License" are protected by the following patents and equivalent patents and patent applications in other countries: US 6,399,750 and EP 1123389. A free, non-transferable limited license to use this product for internal analytical purposes only accompanies the purchase of the product from a Cytiva company and its licensed distributors. Any other use will require a separate license from a Cytiva company.
HiTrap is a registered trademark of Cytiva
MabSelect is a trademark of Cytiva
MabSelect SuRe is a trademark of Cytiva
SuRe is a trademark of Cytiva

象形图

Flame

警示用语:

Warning

危险声明

法规信息

新产品

分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

商品

Desalting at laboratory scale is a well-proven, simple, and fast method that will rapidly remove low molecular weight contaminants at the same time as transferring the sample into the desired buffer in a single step.

实验室规模的脱盐是一种成熟、简单、快速的方法,可以在将样品转移至所需缓冲液的同时快速去除低分子量污染物。

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门