跳转至内容
Merck
CN

C8210

Sigma-Aldrich

2-环己胺基乙磺酸

BioXtra, ≥99.0% (titration)

别名:

2-(环己基氨基)乙磺酸

登录查看公司和协议定价


About This Item

经验公式(希尔记法):
C8H17NO3S
CAS号:
分子量:
207.29
Beilstein:
2967601
EC 号:
MDL编号:
UNSPSC代码:
12161700
PubChem化学物质编号:
NACRES:
NA.25

产品线

BioXtra

质量水平

检测方案

≥99.0% (titration)

形式

powder

杂质

≤0.0005% Phosphorus (P)
≤0.1% Insoluble matter

灼烧残渣

≤0.1%

pH值(酸碱度)

3.0-5.0 (0.5 M in H2O)

有效pH范围

8.6-10.0

pKa (25 °C)

9.3

溶解性

H2O: 0.5 M, clear, colorless

痕量阴离子

chloride (Cl-): ≤0.05%
sulfate (SO42-): ≤0.05%

痕量阳离子

Al: ≤0.0005%
Ca: ≤0.001%
Cu: ≤0.0005%
Fe: ≤0.0005%
K: ≤0.005%
Mg: ≤0.0005%
NH4+: ≤0.05%
Na: ≤0.01%
Pb: ≤0.001%
Zn: ≤0.0005%

吸光度

≤0.05 at 280 in H2O at 0.5 M
≤0.08 at 260 in H2O at 0.5 M

应用

diagnostic assay manufacturing

SMILES字符串

OS(=O)(=O)CCNC1CCCCC1

InChI

1S/C8H17NO3S/c10-13(11,12)7-6-9-8-4-2-1-3-5-8/h8-9H,1-7H2,(H,10,11,12)

InChI key

MKWKNSIESPFAQN-UHFFFAOYSA-N

正在寻找类似产品? 访问 产品对比指南

一般描述

CHES (2-(Cyclohexylamino) ethane sulfonic acid) is a derivative of amino acid taurine. It serves as a standard physiological buffer in the pH range of 8.5-9.5.

应用

CHES may be used:
  • for pH adjustments and as a assay buffer in catechol oxidase activity measurements(32)
  • as a buffer in electron paramagnetic resonance (EPR) spectroscopy and kinetic measurements(33)
  • as a buffer for soil solution equivalent (SSE) yeast dextrose medium for screening pH optima for growth of Aridibacter nitratireducens A24_SHP-5_238T(34)

WGK

WGK 3

闪点(°F)

Not applicable

闪点(°C)

Not applicable

个人防护装备

dust mask type N95 (US), Eyeshields, Gloves


分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Buffers for the physiological pH range: Acidic dissociation constants of zwitterionic compounds (ACES and CHES) in water from 5 to 55? C
Roy RN, et al.
Journal of Chemical and Engineering Data, 42(1), 41-44 (1997)
David G McLaren et al.
Electrophoresis, 24(17), 2887-2895 (2003-09-16)
A systematic evaluation of continuous flow-counterbalanced capillary electrophoresis for microscale preparative applications is presented. The success of the technique was found to depend on the specific nature of the analyte and background electrolyte and was most heavily influenced by factors
P Doble et al.
Electrophoresis, 19(12), 2257-2261 (1998-10-07)
The suitability of relatively slow (low absolute value of mobility) coanionic buffers in background electrolytes (BGEs) for indirect photometric detection of anions by capillary electrophoresis was investigated. As a model system, 2-(cyclohexylamino)ethanesulfonic acid (CHES) was used to buffer the indirect
Scott A Sarver et al.
Journal of chromatography. A, 1229, 268-273 (2012-02-11)
Several glycosphingolipids were labeled with the fluorphore Bodipy-Fl and analyzed using capillary electrophoresis with laser-induced fluorescence detection. GM1-, LacCer-, and Cer-Bodipy-Fl were prepared through acylation using the N-hydroxysuccinimide ester of Bodipy-Fl. Several other glycosphingolipids including GT1a-, GD1a-, GM2-, GM3-, GD3-
R C Bray et al.
Biochemistry, 39(37), 11258-11269 (2000-09-14)
Much is unknown concerning the role of thiolate ligands of molybdenum in molybdopterin enzymes. It has been suggested that thiolate dissociation from molybdenum is part of the catalytic mechanism of bis-molybdopterin enzymes of the dimethyl sulfoxide reductase (DMSOR) family. For

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门