推荐产品
生物来源
rabbit skin
质量水平
描述
acid soluble
表单
powder
技术
cell culture | stem cell: suitable
溶解性
aqueous acid: ≤10 mg/mL
aqueous sodium acetate buffer: soluble (0.01-0.5M)
UniProt登记号
储存温度
2-8°C
基因信息
rabbit ... COL1A2(100008997)
一般描述
Collagen is classified into a number of structurally and genetically distinct types. We use the nomenclature proposed by Bornstein and Traub. Do not confuse Sigma type designations with recognized collagen classification types.
应用
Collagen-type 1 may be used in research of Idiopathic pulmonary fibrosis (IPF). Robust expression of collagen-type 1 is one distinctive feature of IPF. Additionally, collagen-type 1 has been used in studies on the effect of endoplasmic reticulum (ER) stress from IPF on myofibroblastic differentiation of lung fibroblasts. Collage-type 1 soluble in acidic solution produces three dimensional scaffolding useful in bioengineering and cell culture applications where biomaterials are needed to replace native collagen extracellular matrices.
Collagen Type I has been used as a scaffold for the growth in vitro of stem cells in a wide variety of biomaterial engineering studies.
Collagen Type I has been used as a scaffold for the growth in vitro of stem cells in a wide variety of biomaterial engineering studies.
制备说明
Prepared with modification of Gallop, P.M.
储存分类代码
11 - Combustible Solids
WGK
WGK 1
闪点(°F)
Not applicable
闪点(°C)
Not applicable
个人防护装备
Eyeshields, Gloves, type N95 (US)
法规信息
新产品
历史批次信息供参考:
Chirality, 23(9), 801-807 (2011-12-03)
Fourier transform infrared vibrational circular dichroism (FTIR-VCD) measurements have gone through major advances in the last decade. A major thrust in these advances was to find ways that can minimize the VCD spectral artifacts and obtain the VCD signals at
Current opinion in ophthalmology, 24(4), 302-309 (2013-05-18)
Topography-guided laser refractive surgery regularizes the front corneal surface irregularities to achieve the desired refractive outcome. This is particularly applicable in highly aberrated corneas, where wavefront aberrometry is often not possible. This article aims to review the recently published results
European journal of oral implantology, 6(2), 169-179 (2013-08-09)
To compare the clinical effectiveness of two implant systems: Way Milano and Kentron (Geass, Pozzuolo del Friuli, UD, Italy). A total of 64 patients requiring at least two single crowns or partial fixed dental prostheses supported by a maximum of
European journal of oral implantology, 6(2), 153-165 (2013-08-09)
To compare the efficacy of 1-stage versus 2-stage lateral maxillary sinus lift procedures. Sixty partially edentulous patients requiring 1 to 3 implants and having 1 to 3 mm of residual bone height and at least 5 mm of bone width
European journal of oral implantology, 7(1), 65-75 (2014-06-04)
To compare the efficacy of 1-stage versus 2-stage lateral maxillary sinus lift procedures. Sixty partially edentulous patients requiring 1 to 3 implants and having 1 to 3 mm of residual bone height and at least 5 mm bone width below
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门