推荐产品
产品线
BioXtra
方案
≥99.0% (titration)
表单
crystalline
杂质
≤0.0005% Phosphorus (P)
≤0.1% Insoluble matter
灼烧残渣
≤0.2%
pH值(酸碱度)
2.5-5.0 (25 °C, 213.3 g/L)
有效pH范围
6.4-7.8
pKa (25 °C)
7.1
溶解性
H2O: 1 M, clear, colorless
痕量阴离子
chloride (Cl-): ≤0.05%
sulfate (SO42-): ≤0.05%
痕量阳离子
Al: ≤0.0005%
Ca: ≤0.0005%
Cu: ≤0.0005%
Fe: ≤0.0005%
K: ≤0.005%
Mg: ≤0.0005%
NH4+: ≤0.05%
Na: ≤0.005%
Pb: ≤0.001%
Zn: ≤0.0005%
吸附
≤0.080 at 280 in H2O at 1 M
≤0.095 at 260 in H2O at 1 M
SMILES字符串
OCCN(CCO)CCS(O)(=O)=O
InChI
1S/C6H15NO5S/c8-4-1-7(2-5-9)3-6-13(10,11)12/h8-9H,1-6H2,(H,10,11,12)
InChI key
AJTVSSFTXWNIRG-UHFFFAOYSA-N
正在寻找类似产品? 访问 产品对比指南
储存分类代码
11 - Combustible Solids
WGK
WGK 3
闪点(°F)
Not applicable
闪点(°C)
Not applicable
个人防护装备
dust mask type N95 (US), Eyeshields, Gloves
Yingjie Zhang et al.
Nano letters, 15(7), 4657-4663 (2015-06-24)
Noncrystalline semiconductor materials often exhibit hysteresis in charge transport measurements whose mechanism is largely unknown. Here we study the dynamics of charge injection and transport in PbS quantum dot (QD) monolayers in a field effect transistor (FET). Using Kelvin probe
Russell A Jensen et al.
The journal of physical chemistry letters, 6(15), 2933-2937 (2015-08-13)
Colloidal CdSe quantum dot (QD) core ensembles were photodimmed and allowed to recover in the dark using ambient thermal energy at a range of temperatures. Nonlinear thermal recovery is well described by a stretched exponential function, and further analysis yields
Kensuke Nishimiya et al.
Circulation journal : official journal of the Japanese Circulation Society, 79(6), 1323-1331 (2015-04-07)
Coronary adventitia harbors a wide variety of components, such as inflammatory cells and vasa vasorum (VV). Adventitial VV initiates the development of coronary artery diseases as an outside-in supply route of inflammation. We have recently demonstrated that drug-eluting stent implantation
John A Ormiston et al.
EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology, 10(12), 1449-1455 (2014-11-26)
Stent fracture is important because it may cause adverse events. The interventional cardiologist needs independent data to aid stent selection. Stent designers need data to improve stent design. We used a repetitive bend test to compare durability and fracture for
Christos V Bourantas et al.
International journal of cardiology, 186, 178-185 (2015-04-02)
Numerous studies have demonstrated an association between endothelial shear stress (ESS) and neointimal formation after stent implantation. However, the role of ESS on the composition of neointima and underlying plaque remains unclear. Patients recruited in the Comfortable AMI-IBIS 4 study
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门