推荐产品
产品名称
N-(4-氨基丁基)-N-乙基异鲁米诺, ≥90%
质量水平
方案
≥90%
表单
powder
mp
259-260 °C (lit.)
溶解性
glacial acetic acid: 50 mg/mL, clear, colorless to yellow
储存温度
2-8°C
SMILES字符串
CCN(CCCCN)c1ccc2C(=O)NNC(=O)c2c1
InChI
1S/C14H20N4O2/c1-2-18(8-4-3-7-15)10-5-6-11-12(9-10)14(20)17-16-13(11)19/h5-6,9H,2-4,7-8,15H2,1H3,(H,16,19)(H,17,20)
InChI key
LEOJISUPFSWNMA-UHFFFAOYSA-N
正在寻找类似产品? 访问 产品对比指南
相关类别
特点和优势
高效的化学发光 NH2 偶联试剂,用于检测低至皮摩尔范围的各种蛋白质。
其他说明
据报道,在化学发光测定中使用这种材料具有明显优于传统放射免疫测定的优点。
储存分类代码
11 - Combustible Solids
WGK
WGK 3
闪点(°F)
Not applicable
闪点(°C)
Not applicable
个人防护装备
Eyeshields, Gloves, type N95 (US)
历史批次信息供参考:
分析证书(COA)
Chemical communications (Cambridge, England), 48(5), 699-701 (2011-12-03)
We report on a novel strategy to improve microfluidic immunoassay sensitivity by introducing chemiluminescence resonance energy transfer (CRET) into the immunoreactions. The proposed CRET-based immunoassay for estradiol (E2, as a model analyte) is one of the most sensitive immunoassay with
Nature communications, 8(1), 1003-1003 (2017-10-19)
Most known chemiluminescence (CL) reactions exhibit flash-type light emission. Great efforts have been devoted to the development of CL systems that emit light with high intensity and long-lasting time. However, a long-lasting CL system that can last for hundreds of hours
Analytical biochemistry, 393(1), 105-110 (2009-06-23)
A microchip electrophoresis (MCE) method with chemiluminescence (CL) detection was developed for the determination of carnosine-related peptides, including carnosine, homocarnosine, and anserine, in biological samples. A simple integrated MCE-CL system was built to perform the assays. The highly sensitive CL
Journal of chromatography, 615(1), 97-110 (1993-05-19)
N-(4-Aminobutyl)-N-ethylisoluminol was used for labelling of carboxylic acids. The derivatization reaction was carried out with 1-hydroxybenzotriazole as pre-activator of the carboxylic acid function and N-ethyl-N'-(3-dimethylaminopropyl)carbodiimide as the coupling reagent. Optimum conditions for the derivatization were determined by using factorial design
Journal of immunoassay, 7(3), 169-179 (1986-01-01)
Chemiluminescent labels have been shown to be interesting alternatives to radioisotope labels. Disadvantages of the latter are preparation of e.g. labelled protein/peptides every four to six weeks, and problems with storage and disposal. Amino-Butyl-Ethyl-Isoluminol(ABEI) was attached to the alpha-amino function