推荐产品
质量水平
检测方案
99.0-101.0% (T)
形式
crystals
浓度
18.5-20.5% Na
缺失
≤2.0% loss on drying
pH值(酸碱度)
4.5-5.1
溶解性
water: 3.54 g/30 mL, colorless
痕量阳离子
Al: ≤5 mg/kg
Ba: ≤5 mg/kg
Bi: ≤5 mg/kg
Ca: ≤50 mg/kg
Cd: ≤5 mg/kg
Co: ≤5 mg/kg
Cr: ≤5 mg/kg
Cu: ≤5 mg/kg
Fe: ≤5 mg/kg
K: ≤50 mg/kg
Li: ≤5 mg/kg
Mg: ≤5 mg/kg
Mn: ≤5 mg/kg
Mo: ≤5 mg/kg
Ni: ≤5 mg/kg
Pb: ≤5 mg/kg
Sr: ≤5 mg/kg
Zn: ≤5 mg/kg
紫外吸收
λ: 260 nm Amax: ≤0.2
λ: 280 nm Amax: ≤0.07
适用性
no residue for filter test
SMILES字符串
O=P(C)(O[Na])O
InChI
1S/CH5O3P.Na/c1-5(2,3)4;/h1H3,(H2,2,3,4);/q;+1/p-1
InChI key
CZVWTNTXBUVAFR-UHFFFAOYSA-M
应用
Buffer component for ERLIC technique for Phosphoproteome analysis and inhibitor of protein phosphatases.
警示用语:
Danger
危险声明
危险分类
Acute Tox. 4 Oral - Eye Dam. 1 - Skin Corr. 1B
WGK
WGK 3
闪点(°F)
Not applicable
闪点(°C)
Not applicable
法规信息
监管及禁止进口产品
Journal of the American Chemical Society, 134(14), 6326-6336 (2012-03-08)
The mechanism of nucleation, steady-state growth, and repair is investigated for an oxygen evolving catalyst prepared by electrodeposition from Co(2+) solutions in weakly basic electrolytes (Co-OEC). Potential step chronoamperometry and atomic force microscopy reveal that nucleation of Co-OEC is progressive
Proceedings of the National Academy of Sciences of the United States of America, 78(10), 6271-6275 (1981-10-01)
The intracellular pH of Escherichia coli cells, respiring on endogenous energy sources, was monitored continuously by 31P NMR over an extracellular pH range between 5.5 and 9. pH homeostasis was found to be good over the entire range, with the
Pesticide biochemistry and physiology, 109, 34-43 (2014-03-04)
The toxicity of herbicides to animals and human is an issue of worldwide concern. The present study was undertaken to evaluate toxic potential of widely used pesticide - glyphosate, its metabolites: aminomethylphosphonic acid (AMPA); methylphosphonic acid and its impurities: N-(phosphonomethyl)iminodiacetic
Journal of proteome research, 11(8), 4269-4276 (2012-07-10)
In large-scale phosphoproteomics studies, fractionation by strong cation exchange (SCX) or electrostatic repulsion-hydrophilic interaction chromatography (ERLIC) is commonly used to reduce sample complexity, fractionate phosphopeptides from their unmodified counterparts, and increase the dynamic range for phosphopeptide identification. However, these procedures
Journal of proteome research, 10(8), 3474-3483 (2011-06-21)
Reversible phosphorylations play a critical role in most biological pathways. Hence, in signaling studies great effort has been put into identification of a maximum number of phosphosites per experiment. Mass spectrometry (MS)-based phosphoproteomics approaches have been proven to be an
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门