推荐产品
质量水平
方案
≥97.0% (HPLC)
表单
solid
储存温度
−20°C
SMILES字符串
NC1=NC(=O)C2=C(NCC(=N2)[C@H](O)[C@H](O)CO)N1
InChI
1S/C9H13N5O4/c10-9-13-7-5(8(18)14-9)12-3(1-11-7)6(17)4(16)2-15/h4,6,15-17H,1-2H2,(H4,10,11,13,14,18)/t4-,6+/m1/s1
InChI key
YQIFAMYNGGOTFB-XINAWCOVSA-N
警示用语:
Warning
危险声明
危险分类
Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3
靶器官
Respiratory system
储存分类代码
11 - Combustible Solids
WGK
WGK 3
闪点(°F)
Not applicable
闪点(°C)
Not applicable
个人防护装备
dust mask type N95 (US), Eyeshields, Gloves
Christiane Enzinger et al.
European journal of cell biology, 81(4), 197-202 (2002-05-23)
Activated cell-mediated immunity is known to be accompanied by elevated concentrations of 7,8-dihydroneopterin which in high concentrations was found to interfere with the oxidant-antioxidant balance. In this study we investigated whether 7,8-dihydroneopterin mediates apoptosis of Jurkat T-lymphocytes via a CrmA-
Renate Horejsi et al.
Biochimica et biophysica acta, 1571(2), 124-130 (2002-06-07)
7,8-Dihydroneopterin and neopterin are secreted by human and primate macrophages after activation by interferon-gamma in a ratio of 2:1. 7,8-Dihydroneopterin is known to suppress radical-mediated processes, but it is also able in the presence of iron ions to generate superoxide
S P Gieseg et al.
British journal of pharmacology, 153(4), 627-635 (2007-08-19)
The rise in plasma neopterin observed with increasing severity of vascular disease is a strong indicator of the inflammatory nature of atherosclerosis. Plasma neopterin originates as the oxidation product of 7,8-dihydroneopterin secreted by gamma-interferon stimulated macrophages within atherosclerotic plaques. Neopterin
Barbara Wirleitner et al.
Clinical immunology (Orlando, Fla.), 107(3), 152-159 (2003-06-14)
Neopterin (Neo) and 7,8-dihydroneopterin (H(2)Neo) are produced by human monocyte-derived macrophages upon stimulation with IFN-gamma. Increased amounts of Neo and H(2)Neo in human body fluids are found in many disorders, including viral infections and autoimmune diseases. Recent data suggest that
Elizabeth A Flavall et al.
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences, 863(1), 167-171 (2008-02-01)
Measurement of plasma neopterin by HPLC with fluorescence detection is used clinically as a marker of immune cell activation in the management of a number of disease pathologies. HPLC analysis of neopterin requires the acidic removal of plasma proteins but
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门