跳转至内容
Merck
CN

01140

Sigma-Aldrich

氟化锂

purum, ≥99%

别名:

氟石

登录查看公司和协议定价


About This Item

线性分子式:
LiF
CAS号:
分子量:
25.94
EC 号:
MDL编号:
UNSPSC代码:
12352302
PubChem化学物质编号:

等级

purum

方案

≥99%

缺失

≤0.5% loss on ignition, 400 °C, 15 min.

mp

845 °C (lit.)

密度

2.64 g/mL at 25 °C (lit.)

痕量阴离子

chloride (Cl-): ≤50 mg/kg
sulfate (SO42-): ≤500 mg/kg

痕量阳离子

Fe: ≤50 mg/kg

SMILES字符串

[Li+].[F-]
[Li+].[F-]

InChI

1S/FH.Li/h1H;/q;+1/p-1

InChI key

PQXKHYXIUOZZFA-UHFFFAOYSA-M

正在寻找类似产品? 访问 产品对比指南

象形图

Skull and crossbones

警示用语:

Danger

危险分类

Acute Tox. 3 Oral - Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3

靶器官

Respiratory system

补充剂危害

储存分类代码

6.1D - Non-combustible acute toxic Cat.3 / toxic hazardous materials or hazardous materials causing chronic effects

WGK

WGK 2

闪点(°F)

Not applicable

闪点(°C)

Not applicable

法规信息

新产品

历史批次信息供参考:

分析证书(COA)

Lot/Batch Number

抱歉,我们目前尚未线上提供该产品的COA。

如需帮助,请联系 客户支持

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

X W Meng et al.
The journal of physical chemistry. B, 115(16), 4768-4773 (2011-04-06)
On the basis of molecular dynamics simulations, we investigate water permeation across a single-walled carbon nanotube (SWCNT) under the influence of four symmetrical half-rings, each having six LiF dipolar molecules. The flux remains almost fixed as the separation, R, between
Hatem Dachraoui et al.
Optics express, 19(3), 2797-2804 (2011-03-04)
We report a femtosecond crystallographic study of the dependence of the free-carries generation to the alignment of a crystalline sample to the laser polarization. The probe pulse transmission exhibits a π/2 modulation that is shown to be correlated with the
Christian Bernhardsson et al.
Health physics, 103(6), 740-749 (2012-11-01)
Laboratory studies have shown that ordinary household salt (NaCl) exhibits several promising properties for retrospective dosimetry; e.g., a linear dose response and a low detection limit, down to a few mGy or even less. In an attempt to test NaCl
R Takam et al.
Radiation protection dosimetry, 150(1), 22-33 (2011-08-30)
(6)LiF:Mg,Cu,P and (7)LiF:Mg,Cu,P glass-rod thermoluminescent dosemeters (TLDs) were used for measurements of out-of-field photon and neutron doses produced by Varian iX linear accelerator. Both TLDs were calibrated using 18-MV X-ray beam to investigate their dose-response sensitivity and linearity. CR-39 etch-track
Thorsten Grünheid et al.
American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics, 141(4), 436-443 (2012-04-03)
Cone-beam computed tomography (CBCT) has become a routine imaging modality for many orthodontic clinics. However, questions remain about the amount of radiation patients are exposed to during the scans. This study determined the amounts of radiation potentially absorbed by a

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门