推荐产品
等级
pharmaceutical primary standard
API类
metolazone
制造商/商品名称
EDQM
应用
pharmaceutical (small molecule)
包装形式
neat
储存温度
2-8°C
SMILES字符串
CC1Nc2cc(Cl)c(cc2C(=O)N1c3ccccc3C)S(N)(=O)=O
InChI
1S/C16H16ClN3O3S/c1-9-5-3-4-6-14(9)20-10(2)19-13-8-12(17)15(24(18,22)23)7-11(13)16(20)21/h3-8,10,19H,1-2H3,(H2,18,22,23)
InChI key
AQCHWTWZEMGIFD-UHFFFAOYSA-N
基因信息
human ... SLC12A3(6559)
正在寻找类似产品? 访问 产品对比指南
一般描述
This product is provided as delivered and specified by the issuing Pharmacopoeia. All information provided in support of this product, including SDS and any product information leaflets have been developed and issued under the Authority of the issuing Pharmacopoeia.For further information and support please go to the website of the issuing Pharmacopoeia.
应用
Metolazone EP Reference standard, intended for use in laboratory tests only as specifically prescribed in the European Pharmacopoeia.
生化/生理作用
Inhibitor of thiazide-sensitive Na+-Cl- cotransporter; antihypertensive; moderate "loop" diuretic.
包装
The product is delivered as supplied by the issuing Pharmacopoeia. For the current unit quantity, please visit the EDQM reference substance catalogue.
其他说明
Sales restrictions may apply.
储存分类代码
11 - Combustible Solids
WGK
WGK 2
闪点(°F)
Not applicable
闪点(°C)
Not applicable
法规信息
监管及禁止进口产品
Congestive heart failure (Greenwich, Conn.), 9(2), 100-105 (2003-04-03)
Metolazone is commonly administered in conjunction with a loop diuretic to manage volume overload in patients otherwise resistant to loop diuretic therapy alone. Metolazone is a thiazide-type diuretic that is characterized by slow and sometimes erratic absorption when administered as
Pre-dosing metolazone with loop diuretic combination regimens.
Nephrology nursing journal : journal of the American Nephrology Nurses' Association, 33(1), 78-79 (2006-03-17)
Biochemical pharmacology, 92(2), 389-402 (2014-09-03)
Human pregnane X receptor (hPXR) regulates the expression of drug-metabolizing enzyme cytochrome P450 3A4 (CYP3A4) and drug transporters such as multidrug-resistance protein 1 (MDR1). PXR can be modulated by small molecules, including Federal Drug Administration (FDA)-approved drugs, thus altering drug
Luminescence : the journal of biological and chemical luminescence, 29(5), 462-470 (2013-09-03)
A new, specific and sensitive reversed-phase high-performance liquid chromatography method was developed for the simultaneous determination of metolazone (MET) and losartan potassium (LOS). Good chromatographic separation was achieved within 6.0 min on a 150 × 4.6 mm i.d., 5 µm Waters, Ireland
Analytica chimica acta, 853, 647-659 (2014-12-04)
The potential and applicability of UHPSFC-MS/MS for anti-doping screening in urine samples were tested for the first time. For this purpose, a group of 110 doping agents with diverse physicochemical properties was analyzed using two separation techniques, namely UHPLC-MS/MS and
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.