推荐产品
产品线
SpheriCal™
表单
powder
保质期
expiry date on the label
分子量
Mr 1500-3500 Da
组成
9-Nitroanthracene, >90%
sodium trifluoroacetate, <10%
技术
MALDI-MS: suitable
应用
cleaning products
cosmetics
flavors and fragrances
food and beverages
personal care
储存温度
−20°C
正在寻找类似产品? 访问 产品对比指南
一般描述
SpheriCal™ is a dendrimer-based MALDI calibration kit providing 4 monodisperse mass signals per kit for efficient, highly accurate calibration. By combining excellent long-term stability with evenly-spaced calibration points, SpheriCal™ helps users increase the frequency and quality of their MALDI-MS calibrations. With a shelf life of years and each kit offering at least 100 calibration spots, SpheriCal™ offers reliable and accurate calibration across a large mass range, without the shelf-life and storage issues associated with protein or peptide-based systems.
Mass ranges available:
i.SpheriCal™ Mix Peptide Low(m/z 500 - 1,600)
ii.SpheriCal™ Mix Peptide Medium(m/z 1,600 - 3,500)
iii.SpheriCal™ Mix Peptide High (m/z 3,500 - 7,500)
iv.SpheriCal™ Mix Protein Low (m/z 7,500 - 15,000)
v.SpheriCal™ Mix Protein Medium (m/z 15,000 - 30,000)
SpheriCal™ Mix: quick and easy to use - just add solvent.
As calibration standard, matrix and counter ion are pre-mixed in optimized ratios, SpheriCal™ Mix dramatically expedites sample preparation for calibration in minutes. SpheriCal™ Mix 9NA is pre-formulated with 9-nitroanthracene matrix for a robust calibration solution.
Find more information here SpheriCal™
Mass ranges available:
i.SpheriCal™ Mix Peptide Low(m/z 500 - 1,600)
ii.SpheriCal™ Mix Peptide Medium(m/z 1,600 - 3,500)
iii.SpheriCal™ Mix Peptide High (m/z 3,500 - 7,500)
iv.SpheriCal™ Mix Protein Low (m/z 7,500 - 15,000)
v.SpheriCal™ Mix Protein Medium (m/z 15,000 - 30,000)
SpheriCal™ Mix: quick and easy to use - just add solvent.
As calibration standard, matrix and counter ion are pre-mixed in optimized ratios, SpheriCal™ Mix dramatically expedites sample preparation for calibration in minutes. SpheriCal™ Mix 9NA is pre-formulated with 9-nitroanthracene matrix for a robust calibration solution.
Find more information here SpheriCal™
应用
For mass calibration in mass spectrometry
包装
Quantity: 5 mg/vial
法律信息
SpheriCal is a trademark of Polymer Factory Sweden AB
相关产品
产品编号
说明
价格
储存分类代码
13 - Non Combustible Solids
WGK
WGK 3
闪点(°F)
Not applicable
闪点(°C)
Not applicable
相关内容
The Grayson research labs have focused on the synthesis and characterization of well-defined polymers. One particular theme of research has involved the optimization of the mass spectral analysis of polymers using MALDI-TOF MS and associated calibration methodologies.
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门