推荐产品
表单
powder
质量水平
技术
titration: suitable
颜色
white to off-white
mp
181-185 °C (dec.) (lit.)
溶解性
methanol: 1 mg/mL
适用性
suitable for determination of calcium
应用
diagnostic assay manufacturing
hematology
histology
储存温度
room temp
SMILES字符串
Cc1cc(cc(CN(CC(O)=O)CC(O)=O)c1O)C2(OC(=O)c3ccccc23)c4cc(C)c(O)c(CN(CC(O)=O)CC(O)=O)c4
InChI
1S/C32H32N2O12/c1-17-7-21(9-19(29(17)43)11-33(13-25(35)36)14-26(37)38)32(24-6-4-3-5-23(24)31(45)46-32)22-8-18(2)30(44)20(10-22)12-34(15-27(39)40)16-28(41)42/h3-10,43-44H,11-16H2,1-2H3,(H,35,36)(H,37,38)(H,39,40)(H,41,42)
InChI key
IYZPEGVSBUNMBE-UHFFFAOYSA-N
正在寻找类似产品? 访问 产品对比指南
一般描述
邻甲酚酞络合酮(o-Cresolphthalein Complexone)是一种pH指示剂和(金属络合指示剂),常用于通过量热法检测血清中的钙含量。
应用
邻甲酚酞络合酮的应用包括,通过Ca2+和邻甲酚酞络合酮在碱性溶液中的反应检测血清样本中的钙含量。
储存分类代码
11 - Combustible Solids
WGK
WGK 3
闪点(°F)
Not applicable
闪点(°C)
Not applicable
个人防护装备
Eyeshields, Gloves, type N95 (US)
历史批次信息供参考:
Annals of clinical biochemistry, 24 ( Pt 4), 345-351 (1987-07-01)
The reasons for the non-linearity of the standard curve for the calcium-cresolphthalein complexone reaction have been investigated. Calcium forms both 1:1 and 2:1 complexes with cresolphthalein complexone; at low calcium concentrations the 1:1 complex predominates and causes non-linearity. At high
Clinical chemistry, 26(11), 1562-1565 (1980-10-01)
We adapted a method for dialyzable calcium from fluorometric detection by use of calcein to a more specific spectrophotometric determination with cresolphthalein complexone. The reagents are available commercially and perform satisfactorily with respect to noise level, drift, stability, and sensitivity.
American journal of clinical pathology, 82(2), 182-187 (1984-08-01)
An automated calcium method based on o-cresolphthalein complexone chemistry and designed to be used in conjunction with the Beckman ASTRA systems (Beckman Instruments, Inc., Brea, CA) was evaluated. Day-to-day reproducibility studies yielded coefficients of variation ranging from 1.2 to 3.1%.
Radiology, 233(1), 158-164 (2004-09-30)
To measure serum calcium concentration with three different analytic methods after administration of gadoversetamide and three other gadolinium chelates in dogs. Six dogs were injected with 0.1-, 0.3-, 1.0-, and 3.0-mmol/kg doses of gadoversetamide; 1.0-mmol/kg doses of gadodiamide, gadopentetate, and
Clinical chemistry, 27(12), 2025-2028 (1981-12-01)
We describe an automated method for calcium assay, for use with the Cobas-Bio centrifugal analyzer. Calcium is reacted with cresolphthalein complexone and the absorbance of the calcium--dye complex at 575 nm is measured. EDTA is then added to break up