产品名称
Hormones in Frozen Human Serum, NIST®SRM®
packaging
pkg of 4 × 2 mL
manufacturer/tradename
NIST®
technique(s)
mass spectrometry (MS): suitable
application(s)
clinical testing
storage temp.
−70°C
Application
ThisNIST SRM 971a is intended primarily for use in evaluating the accuracy of procedures for the determination of the steroid hormones cortisol, progesterone, and testosterone, and thyroid hormones total thyroxine (T4), and total 3,3′,5-triiodothyronine (T3) in human serum.
It is also intended for use in validating working or secondary reference materials.
It is also intended for use in validating working or secondary reference materials.
Features and Benefits
- A unit of SRM contains two vials of each material. Each vial approximately contains 2 mL of human serum
- Both materials in the SRM are unfortified
General description
A unit of Hormones in Frozen Human Serum standard reference material (SRM) consists of two vials each of two materials: one from a pool of healthy, premenopausal adult females and one from a pool of healthy adult males. The certified values of the SRM were determined using higher-order reference measurement procedures calibrated with high-purity chemical reference standards in combination with higher-order measurement procedures conducted by the CDC. The uncertainties are expanded uncertainties at the 95 % level of confidence. The certified values of the SRM, apply only to serum thawed to room temperature, 20 °C to 25 °C.
SRM 971a_cert
SRM 971a _SDS
SRM 971a_cert
SRM 971a _SDS
Other Notes
- SRM 971a is intended for research use.
- The serum is shipped frozen (on dry ice) and, upon receipt, should be stored frozen until ready for use.
- Expiration details and storage and use instructions are provided on the NIST certificate
- Notes on biomaterial handling, disposal, and transport documented in MSDS
Legal Information
NIST is a registered trademark of National Institute of Standards and Technology
SRM is a registered trademark of National Institute of Standards and Technology
存储类别
10 - Combustible liquids
wgk
WGK 1
flash_point_f
Not applicable
flash_point_c
Not applicable
法规信息
新产品
此项目有
Sung-Eun Cho et al.
Annals of laboratory medicine, 43(1), 19-28 (2022-09-01)
Mass spectrometry methods exhibit higher accuracy and lower variability than immunoassays at low testosterone concentrations. We developed and validated an ultraperformance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) assay for quantifying serum total testosterone. We used an ExionLC UPLC (Sciex, Framingham, MA
Nyasha Munjoma et al.
Journal of proteome research, 21(11), 2596-2608 (2022-10-21)
Lipids play a key role in many biological processes, and their accurate measurement is critical to unraveling the biology of diseases and human health. A high throughput HILIC-based (LC-MS) method for the semiquantitative screening of over 2000 lipids, based on
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系客户支持