M8911

Sigma-Aldrich

4-羟基苯甲酸甲酯

analytical standard

登录查看公司和协议定价

别名:
对羟基苯甲酸甲酯, 对羟苯甲酸甲酯, 尼泊金甲酯
线性分子式:
HOC6H4CO2CH3
CAS号:
分子量:
152.15
Beilstein:
509801
EC 号:
MDL编号:
UNSPSC代码:
51452201
PubChem化学物质编号:
NACRES:
NA.77

等级

analytical standard

质量水平

检测方案

98.0-102.0%

形式

solid

包装

vial of 200 mg

mp

125-128 °C (lit.)

SMILES字符串

COC(=O)c1ccc(O)cc1

InChI

1S/C8H8O3/c1-11-8(10)6-2-4-7(9)5-3-6/h2-5,9H,1H3

InChI key

LXCFILQKKLGQFO-UHFFFAOYSA-N

基因信息

rat ... Ar(24208)

正在寻找类似产品? 访问 产品对比指南

应用

Methyl 4-hydroxybenzoate has been used as an internal standard for the determination of trans-10-hydroxy-2-decenoic acid (10-HDA).

包装

Bottomless glass bottle. Contents are inside inserted fused cone.
Supplied in amber screw-cap vials

象形图

Environment

危险声明

预防措施声明

危险分类

Aquatic Chronic 2

WGK

WGK 1

闪点(°F)

334.4 °F

闪点(°C)

168 °C

个人防护装备

dust mask type N95 (US), Eyeshields, Gloves


分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Comparison of UPLC and HPLC for determination of trans-10-hydroxy-2-decenoic acid content in royal jelly by ultrasound-assisted extraction with internal standard
Zhou J, et al.
Chromatographia, 66(3-4), 185-190 (2007)
Optimized determination method for trans-10-hydroxy-2-decenoic acid content in royal jelly by high-performance liquid chromatography with an internal standard
Zhou J, et al.
Journal of AOAC (Association of Official Analytical Chemists) International, 90(1), 244-249 (2007)
Kyung-Jin Min et al.
Aging cell, 7(2), 199-206 (2008-01-29)
Reduced insulin/insulin-like growth factor (IGF) signaling may be a natural way for the reduction of dietary nutrients to extend lifespan. While evidence challenging this hypothesis is accumulating with Caenorhabditis elegans, for Drosophila melanogaster it is still thought that insulin/IGF and
Gabriela Oliveira et al.
International journal of pharmaceutics, 435(1), 38-49 (2012-05-29)
Simple topical formulations which include volatile components, such as gels or sprays, are appealing from a cosmetic perspective. However, complex formulation effects may result from the use of volatile excipients in topical formulations, particularly when applied at clinically relevant doses
Ismail I Hewala et al.
Talanta, 88, 623-630 (2012-01-24)
Simple methods for HPTLC peak purity assessment and identification of the HPTLC peaks were presented. The spectrodensitograms - selected at different time intervals across the elution time of the HPTLC peak - were extracted and digital algorithms for manipulating the

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门