跳转至内容
Merck
CN

90151

Supelco

17b-羟基-17a-甲基-1,4-雄甾二烯-3-酮

analytical standard

别名:

1-脱氢-17α-甲基睾甾酮, 去氢甲睾酮, 美雄酮, 羟甲雄二烯酮

登录查看公司和协议定价


About This Item

经验公式(希尔记法):
C20H28O2
CAS号:
分子量:
300.44
Beilstein:
2056255
EC 号:
MDL编号:
UNSPSC代码:
41116107
PubChem化学物质编号:
NACRES:
NA.24

等级

analytical standard

质量水平

方案

≥97.0% (HPLC)

旋光性

[α]1.15/D -0.5±0.5° in chloroform

保质期

limited shelf life, expiry date on the label

药品控制

USDEA Schedule IIIN; regulated under CDSA - not available from Sigma-Aldrich Canada

技术

HPLC: suitable
gas chromatography (GC): suitable

应用

clinical testing

包装形式

neat

官能团

ketone

储存温度

2-8°C

SMILES字符串

C[C@]1(O)CC[C@H]2[C@@H]3CCC4=CC(=O)C=C[C@]4(C)[C@H]3CC[C@]12C

InChI

1S/C20H28O2/c1-18-9-6-14(21)12-13(18)4-5-15-16(18)7-10-19(2)17(15)8-11-20(19,3)22/h6,9,12,15-17,22H,4-5,7-8,10-11H2,1-3H3/t15-,16+,17+,18+,19+,20+/m1/s1

InChI key

XWALNWXLMVGSFR-HLXURNFRSA-N

基因信息

human ... AR(367)

正在寻找类似产品? 访问 产品对比指南

一般描述

17β-hydroxy-17-methylandrosta-1,4-dien-3-one is an androgenic anabolic steroid.

应用

17β-hydroxy-17-methylandrosta-1,4-dien-3-one may be used as a reference standard in the determination of 17β-hydroxy-17-methylandrosta-1,4-dien-3-one in urine samples, using by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS).
Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.

包装

Bottomless glass bottle. Contents are inside inserted fused cone.

储存分类代码

11 - Combustible Solids

WGK

WGK 3

闪点(°F)

Not applicable

闪点(°C)

Not applicable

法规信息

监管及禁止进口产品

历史批次信息供参考:

分析证书(COA)

Lot/Batch Number

没有发现合适的版本?

如果您需要特殊版本,可通过批号或批次号查找具体证书。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Comparative study of matrices for their use in the rapid screening of anabolic steroids by matrix?assisted laser desorption/ionisation time?of?flight mass spectrometry
Galesio.M, et al.
Rapid Communications in Mass Spectrometry, 23, 1783-1791 (2009)
Oscar J Pozo et al.
Drug testing and analysis, 1(11-12), 554-567 (2010-04-01)
Anabolic steroids are among the most frequently detected compounds in doping analysis. They are extensively metabolized and therefore an in-depth knowledge about steroid metabolism is needed. In this study, a liquid chromatography tandem mass spectometry (LC-MS/MS) method based on a
Stephanie Mosler et al.
Archives of toxicology, 86(1), 109-119 (2011-08-06)
There is increasing evidence that the biological activity of myostatin (MSTN), a negative regulator of muscle growth, is affected by training but also anabolic steroids. In this study, we analyzed the effects of the frequently abused anabolic steroid methandienone (Md)
Andy Zöllner et al.
Biological chemistry, 391(1), 119-127 (2009-11-19)
Anabolic-androgenic steroids are some of the most frequently misused drugs in human sports. Recently, a previously unknown urinary metabolite of metandienone, 17beta-hydroxymethyl-17 alpha-methyl-18-norandrosta-1,4,13-trien-3-one (20OH-NorMD), was discovered via LC-MS/MS and GC-MS. This metabolite was reported to be detected in urine samples
Linda L Ahonen et al.
Rapid communications in mass spectrometry : RCM, 24(7), 958-964 (2010-03-09)
We examined the feasibility of capillary liquid chromatography/microchip atmospheric pressure photoionization tandem mass spectrometry (capLC/microAPPI-MS/MS) for the analysis of anabolic steroids in human urine. The urine samples were pretreated by enzymatic hydrolysis (with beta-glucuronidase from Helix pomatia), and the compounds

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门