蒸汽密度
3.7 (vs air)
质量水平
蒸汽压
0.26 mmHg ( 25 °C)
等级
purum p.a.
检测方案
≥99.5% (GC)
形式
liquid
自燃温度
899 °F
杂质
≤0.1% water
≤0.5% m- and p-toluidine (GC)
灼烧残渣
≤0.01% (as SO4)
折射率
n20/D 1.572 (lit.)
n20/D 1.572
bp
199-200 °C (lit.)
89-90 °C/11 mmHg (lit.)
mp
−28 °C (lit.)
溶解性
H2O: slightly soluble
密度
1.008 g/mL at 25 °C (lit.)
痕量阳离子
Ca: ≤5 mg/kg
Cd: ≤1 mg/kg
Co: ≤1 mg/kg
Cr: ≤1 mg/kg
Cu: ≤1 mg/kg
Fe: ≤1 mg/kg
K: ≤20 mg/kg
Mg: ≤1 mg/kg
Mn: ≤1 mg/kg
Na: ≤20 mg/kg
Ni: ≤1 mg/kg
Pb: ≤1 mg/kg
Zn: ≤1 mg/kg
SMILES字符串
Cc1ccccc1N
InChI
1S/C7H9N/c1-6-4-2-3-5-7(6)8/h2-5H,8H2,1H3
InChI key
RNVCVTLRINQCPJ-UHFFFAOYSA-N
正在寻找类似产品? 访问 产品对比指南
一般描述
o-Toluidine belongs to the class of monocyclic aromatic amines, which are of research and industrial importance. It can be used as a derivatization agent for the resolution of analytes by the formation of chromophores, which can be visualized by UV radiation or fluorescence.
应用
o-Toluidine may be used as a TLC Visualization (Staining) Reagent for the detection of reducing sugars in protein hydrolysates by using high-performance thin-layer chromatography (HPTLC) coupled with UV diffuse reflectance scanning densitometry.
注意
储存中可能变色
警示用语:
Danger
危险分类
Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Aquatic Acute 1 - Aquatic Chronic 2 - Carc. 1B - Eye Irrit. 2
WGK
WGK 3
个人防护装备
Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter
法规信息
危险化学品
An o-toluidine method for detection of carbohydrates in protein hydrolysates
Analytical Biochemistry, 195(1), 153-159 (1991)
Determination of aromatic amines in textile after bromination, by gas chromatography coupled with electron capture detection
Chromatographia, 59(5-6), 335-341 (2004)
Journal of hazardous materials, 170(2-3), 928-933 (2009-06-23)
Electrochemical oxidation of O-toluidine (OT) was studied by galvanostatic electrolysis using lead dioxide (PbO2) and boron-doped diamond (BDD) as anodes. The influence of operating parameters, such as current density, initial concentration of OT and temperature was investigated. Measurements of chemical
Physical chemistry chemical physics : PCCP, 11(21), 4311-4318 (2009-05-22)
The rotationally resolved spectrum of the o-toluidine S(1)<-- S(0) origin was measured using laser induced fluorescence spectroscopy. From the resulting spectrum torsional barriers to internal rotation of the methyl group were derived, which resulted in S(0) state values of V(3)
Occupational and environmental medicine, 67(5), 348-350 (2009-11-04)
In 1991, the US National Institute for Occupational Safety and Health (NIOSH) reported an increased bladder cancer risk in a cohort of 1749 workers potentially exposed to o-toluidine and aniline at a chemical manufacturing plant. As additional information showed that
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门