跳转至内容
Merck
CN

87158

Supelco

1-十四醇

Selectophore, ≥99.0%

别名:

十四醇, 肉豆蔻醇

登录查看公司和协议定价


About This Item

线性分子式:
CH3(CH2)13OH
CAS号:
分子量:
214.39
Beilstein:
1742652
EC 号:
MDL编号:
UNSPSC代码:
26111700
PubChem化学物质编号:
NACRES:
NA.05

等级

for ion-selective electrodes

质量水平

蒸汽密度

7.4 (vs air)

产品线

Selectophore

方案

≥99.0% (GC)
≥99.0%

表单

powder

自燃温度

489 °F

沸点

289 °C (lit.)

mp

35-39 °C (lit.)
38-39 °C

密度

0.823 g/mL at 25 °C (lit.)

SMILES字符串

CCCCCCCCCCCCCCO

InChI

1S/C14H30O/c1-2-3-4-5-6-7-8-9-10-11-12-13-14-15/h15H,2-14H2,1H3

InChI key

HLZKNKRTKFSKGZ-UHFFFAOYSA-N

正在寻找类似产品? 访问 产品对比指南

一般描述

请访问 传感器应用门户网站 了解更多信息。

法律信息

Selectophore is a trademark of Merck KGaA, Darmstadt, Germany

象形图

Exclamation markEnvironment

警示用语:

Warning

危险声明

危险分类

Aquatic Chronic 1 - Eye Irrit. 2

储存分类代码

11 - Combustible Solids

WGK

WGK 2

闪点(°F)

298.4 °F - closed cup

闪点(°C)

148 °C - closed cup

个人防护装备

dust mask type N95 (US), Eyeshields, Gloves


历史批次信息供参考:

分析证书(COA)

Lot/Batch Number

没有发现合适的版本?

如果您需要特殊版本,可通过批号或批次号查找具体证书。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Cosmetic allergy from myristyl alcohol.
A C de Groot et al.
Contact dermatitis, 19(1), 76-77 (1988-07-01)
Self-assembled transparent conductive electrodes from Au nanoparticles in surfactant monolayer templates.
Ahiud Morag et al.
Advanced materials (Deerfield Beach, Fla.), 23(37), 4327-4331 (2011-11-01)
Yijun Du et al.
Virus research, 147(2), 294-299 (2009-12-03)
The small envelope (E) protein of porcine reproductive and respiratory syndrome virus (PRRSV) is known to possess the properties of an ion-channel protein, and in the present study we show that the PRRSV E protein is N-terminal myristoylated. The PRRSV
G B Zavoico et al.
Biochimica et biophysica acta, 812(2), 299-312 (1985-01-25)
The perturbing effects of n-alkanols (pentanol, decanol and tetradecanol) in egg phosphatidylcholine and dipalmitoylphosphatidylcholine multilamellar vesicles were studied with five fluorescent probes, 1-(4'-trimethylaminophenyl)-6-phenylhexa-1,3,5-triene (TMA-DPH), 1,6-diphenyl-1,3,5-hexatriene, and 2-, 7-, and 12-(9-anthroxyloxy)stearic acid (2-, 7-, and 12-AS). These probes localize at various
H Komamura et al.
Contact dermatitis, 36(1), 44-46 (1997-01-01)
A 29-year-old man being treated for itchy lesions on the amputation stump of the thigh became allergic to betamethasone valerate and gentamicin sulfate cream (Rinderon VG). Closed patch tests with all the ingredients of the cream revealed positive reactions to

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门