跳转至内容
Merck
CN

85409

Sigma-Aldrich

硅油

for oil baths (from −50°C to +200°C)

别名:

Dimethyl polysiloxane

登录查看公司和协议定价


About This Item

线性分子式:
[-Si(CH3)2O-]n
CAS号:
MDL编号:
UNSPSC代码:
12352100
NACRES:
NA.21

等级

for oil baths (from −50°C to +200°C)

质量水平

蒸汽密度

>1 (vs air)

蒸汽压

<5 mmHg ( 25 °C)
5 mmHg ( 20 °C)

表单

oil

折射率

n20/D 1.403 (lit.)
n20/D 1.406

粘度

100 mPa.s(20 °C)

沸点

>140 °C/0.002 mmHg (lit.)

密度

0.967 g/mL at 20 °C

正在寻找类似产品? 访问 产品对比指南

一般描述

硅油用于制备温度在-50°C到+200°C范围内的油浴。
硅油通常用于研究实验室的油浴,用于需要在 -50°C 至 +200°C 范围内加热/回流温度的反应。与其他加热设备相比,油浴提供更均匀的热量。

应用

硅油在一项研究中被用作保护碳钢合金试样。硅油在NMR(核磁共振)分析中也被用作热源。

储存分类代码

10 - Combustible liquids

WGK

WGK 1

闪点(°F)

214.0 °F - closed cup

闪点(°C)

101.1 °C - closed cup

个人防护装备

Eyeshields, Gloves


历史批次信息供参考:

分析证书(COA)

Lot/Batch Number

没有发现合适的版本?

如果您需要特殊版本,可通过批号或批次号查找具体证书。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Low-temperature atomic layer deposition of Al2O3 thin coatings for corrosion protection of steel: surface and electrochemical analysis.
Diaz B, et al.
Corrosion Science, 53(6), 2168-2175 (2011)
M Findeisen et al.
Magnetic resonance in chemistry : MRC, 45(2), 175-178 (2006-12-13)
Most established NMR thermometers rely on temperature-dependent chemical shift differences measured from samples that are either neat or concentrated solutions (e.g. ethylene glycol, methanol). These are unsuitable for modern cryoprobes on account of strong radiation damping resulting from the high
Florent Badique et al.
Biomaterials, 34(12), 2991-3001 (2013-01-30)
We have recently demonstrated strong nuclear deformation of SaOs-2 osteosarcoma cells on poly-L-lactic acid (PLLA) micropillar substrates. In the present study, we first demonstrated that chemical and mechanical properties of the micropillar substrates have no dominant effect on deformation. However
Karthik R Balakrishnan et al.
Lab on a chip, 13(7), 1302-1307 (2013-02-07)
Resistive-pulse sensing (RPS), which is based on measuring the current pulse produced when a single particle transits a pore or channel, is an extremely versatile technique used to determine the size and concentration of cells and viruses and to detect
John R Fowler et al.
The Orthopedic clinics of North America, 44(3), 425-431 (2013-07-06)
Radial head fractures without associated bony or ligamentous injury can be safely treated with internal fixation, if possible, or arthroplasty if nonreconstructable. However, nonreconstructable radial head fractures in association with elbow dislocation and/or ligamentous injury in the elbow or forearm

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.