跳转至内容
Merck
CN

56677

Supelco

甲醛-2,4-DNPH

certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland

登录查看公司和协议定价

别名:
甲醛-2,4-二硝基苯腙
线性分子式:
H2C=NNHC6H3(NO2)2
CAS号:
分子量:
210.15
Beilstein:
750330
MDL编号:
UNSPSC代码:
41116107
PubChem化学物质编号:
NACRES:
NA.24

等级

certified reference material
TraceCERT®

质量水平

产品线

TraceCERT®

保质期

limited shelf life, expiry date on the label

制造商/商品名称

Manufactured by: Sigma-Aldrich Production GmbH, Switzerland

储存条件

under inert gas (Argon)

技术

gas chromatography (GC): suitable

mp

153-156 °C (lit.)

格式

neat

储存温度

2-8°C

SMILES字符串

[O-][N+](=O)c1ccc(NN=C)c(c1)[N+]([O-])=O

InChI

1S/C7H6N4O4/c1-8-9-6-3-2-5(10(12)13)4-7(6)11(14)15/h2-4,9H,1H2

InChI key

UEQLSLWCHGLSML-UHFFFAOYSA-N

正在寻找类似产品? 访问 产品对比指南

一般描述

This certified reference material (CRM) is produced and certified in accordance with ISO/IEC 17025 and ISO 17034. This CRM is traceable to primary material from an NMI, e.g. NIST or NMIJ.
Certified content by quantitative NMR incl. uncertainty and expiry date are given on the certificate.
Download your certificate at: http://www.sigma-aldrich.com.

应用


  • Amine-impregnated dendritic mesoporous silica for formaldehyde adsorption: A study demonstrated the use of amine-impregnated dendritic mesoporous silica for effective formaldehyde adsorption, showcasing its potential in enhancing environmental safety and occupational health in settings with volatile formaldehyde emissions (Lee et al., 2023).

法律信息

TraceCERT is a registered trademark of Merck KGaA, Darmstadt, Germany

象形图

Exclamation mark

警示用语:

Warning

危险声明

危险分类

Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3

靶器官

Respiratory system

WGK

WGK 3

闪点(°F)

Not applicable

闪点(°C)

Not applicable


分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Nicola Mucci et al.
La Medicina del lavoro, 110(6), 446-458 (2019-12-18)
In recent years, under-vacuum sealing (UVS) and containers with formalin encapsulated in the lid have been proposed for the reduction of occupational exposure to airborne formaldehyde (FA) in healthcare environments. We are presenting a study focused on the assessment of
Ikuo Ueta et al.
Analytical and bioanalytical chemistry, 407(3), 899-905 (2014-09-10)
A novel miniaturized sample extraction capillary was developed to provide a simple and sensitive method for analyzing gaseous formaldehyde (FA) using conventional high-performance liquid chromatography (HPLC). The extraction capillary was prepared by packing silica gel particles in a stainless steel

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门