跳转至内容
Merck
CN

52411

Supelco

七氟丁酸

suitable for ion chromatography, ≥99.5% (GC)

登录查看公司和协议定价

别名:
HFBA, 全氟丁酸, 埃德曼试剂3号
线性分子式:
CF3CF2CF2COOH
CAS号:
分子量:
214.04
Beilstein:
1426882
EC 号:
MDL编号:
UNSPSC代码:
12000000
PubChem化学物质编号:
NACRES:
NB.21

蒸汽密度

7 (vs air)

质量水平

蒸汽压

~10 mmHg ( 25 °C)

描述

anionic

检测方案

≥99.5% (GC)

形式

liquid

保质期

limited shelf life, expiry date on the label

技术

ion chromatography: suitable

折射率

n20/D 1.3 (lit.)

bp

120 °C/755 mmHg (lit.)

密度

1.645 g/mL at 25 °C (lit.)

痕量阳离子

Al: ≤0.5 mg/kg
Ba: ≤0.01 mg/kg
Bi: ≤0.01 mg/kg
Ca: ≤2 mg/kg
Cd: ≤0.01 mg/kg
Co: ≤0.01 mg/kg
Cr: ≤0.01 mg/kg
Cu: ≤0.01 mg/kg
Fe: ≤0.1 mg/kg
K: ≤0.5 mg/kg
Li: ≤0.01 mg/kg
Mg: ≤1 mg/kg
Mn: ≤0.01 mg/kg
Mo: ≤0.01 mg/kg
Na: ≤3 mg/kg
Ni: ≤0.01 mg/kg
Pb: ≤0.01 mg/kg
Sr: ≤0.01 mg/kg
Zn: ≤0.05 mg/kg

SMILES字符串

OC(=O)C(F)(F)C(F)(F)C(F)(F)F

InChI

1S/C4HF7O2/c5-2(6,1(12)13)3(7,8)4(9,10)11/h(H,12,13)

InChI key

YPJUNDFVDDCYIH-UHFFFAOYSA-N

正在寻找类似产品? 访问 产品对比指南

应用

在从蜥蜴爪中测序富含甘氨酸的蛋白质的实验中,七氟丁酸(HFBA)被用于切割甘氨酰丝氨酸键,。

联系

访问 IC 网站 了解更多

相关产品

产品编号
说明
价格

象形图

Corrosion

警示用语:

Danger

危险声明

危险分类

Skin Corr. 1A

WGK

WGK 3

闪点(°F)

Not applicable

闪点(°C)

Not applicable

个人防护装备

Faceshields, Gloves, Goggles, type ABEK (EN14387) respirator filter

法规信息

危险化学品

分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Sequence of a glycine-rich protein from lizard claw: unusual dilute acid and heptafluorobutyric acid cleavages.
Inglis A
Proteins: Structure, Function, and Genetics, 757-764 (1987)
Ulrika Eriksson et al.
Environmental science and pollution research international, 20(11), 7940-7948 (2013-04-17)
Diet and drinking water are suggested to be major exposure pathways for perfluoroalkyl substances (PFASs). In this study, food items and water from Faroe Islands sampled in 2011/2012 were analyzed for 11 perfluoroalkyl carboxylic acids (PFCAs) and 4 perfluoroalkane sulfonic
V Gellrich et al.
Chemosphere, 87(9), 1052-1056 (2012-03-07)
Perfluorinated compounds (PFCs) can be detected worldwide in both, soil and water. In order to study the leaching behavior of this heterogeneous group of compounds in soil, flow-through column experiments have been conducted. Ten perfluoro carboxylates and four perfluoro sulfonates
Kaberi P Das et al.
Toxicological sciences : an official journal of the Society of Toxicology, 105(1), 173-181 (2008-05-31)
Perfluorobutyrate (PFBA) is a perfluoroalkyl acid (PFAA) found in the environment. Previous studies have indicated developmental toxicity of PFAAs (perfluorooctane sulfonate [PFOS] and perfluorooctanoate [PFOA]); the current study examines that of PFBA. PFBA/NH4(+) was given to timed-pregnant CD-1 mice by
Merja R Häkkinen et al.
Journal of pharmaceutical and biomedical analysis, 45(4), 625-634 (2007-10-20)
A reversed phase liquid chromatography-electrospray ionization-tandem mass spectrometric method (RP-LC-ESI-MS/MS) was developed to separate and detect polyamines with minimal sample pre-treatment and without any derivatization. Prior to MS/MS analysis, a complete chromatographic separation of polyamines was achieved by a linear

商品

LC/LC-MS method identifies 8 aminoglycosides in pork using Discovery® DSC-18 SPE and Ascentis® Express C18 UHPLC, per Chinese standards.

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门